Measurement of ion recombination correction factors for plane parallel ionization chambers
نویسندگان
چکیده
The work presented focuses on the measurement of Ja e plots and determination of ion recombination factors for plane parallel ionisation chambers used in pulsed electron beams. The ability to measure the Ja e plots accurately is useful when commisioning a new chamber and the ion recombination correction factor needs to be known when the chamber is calibrated in a beam quality di erent from the user beam. In this study the ion recombination factor is measured and Ja e plots are produced for three di erent plane parallel chambers. A Roos chamber type 34001 (PTW Freiburg), a plane parallel NACP chamber type -02 (Scanditronix) and a plane parallel Pitman chamber (631). Experimental results are presented in form of Ja e plots, as well as the ion recombination correction factor, determined both from Ja e plots and by means of the two voltage method as recommended in IAEA TRS-398. The report also presents results dealing with the measurement technique and experimental setup. Drift, leakage and polarity e ect are discussed. The methods of statistical analysis are brought up and discussion is made regarding the validity of the statistical analysis. The measurements were performed on an Elekta linear accelerator at Perth Radiation Oncology, Wembley, Perth WA. Energies between 6 and 15 MeV were used with doses per pulse below 0.02 cGy per pulse. The project goal was to measure the ion recombination correction factor and produce a Ja e plot for a plane parallell Pitman chamber that during various other measurements have shown discrepancy from other chambers. In the goal was also included measurment of the ion recombination factor and Ja e plot for a plane parallel Roos chamber and a plane parallel NACP chamber to allow for a comparison to be made between chambers. The Pitman chamber was found to have a deviation from linearity of the Ja e plot at lower voltages than the other chambers.
منابع مشابه
Effective Point of Measurement in Cylindrical Ion Chamber for Megavoltage Photon Beams
Introduction For dose measurement in Megavoltage (MV) photon beams with ion chambers, the effect of volume occupied by the air cavity is not negligible. Therefore, the result of measurement should be corrected with a displacement perturbation correction factor (Pdis) or using an effective point of measurement (EPOM). The aim of this study is to calculate the EPOM for cylindrical ion chamber and...
متن کاملIon recombination corrections of ionization chambers in flattening filter‐free photon radiation
The flattening filter free (FFF) X-rays can provide much higher dose rate at the treatment target compared to the conventional flattened X-rays. However, the substantial increase of dose rate for FFF beams may affect the ion recombination correction factor, which is required for accurate measurements using ionization chambers in clinical dosimetry. The purpose of this work is to investigate the...
متن کاملPolarity and Ion Recombination Correction Factors of a Thimble Type Ionization Chamber with Depth in Water in the Megavoltage Beams
When the PDD (percentage depth dose) in the megavoltage beams is measured in the water phantom using the dosimetry system, the polarity and ion recombination effects of ionization chambers with depth in water are not usually taken into consideration. The polarity and ion recombination effects may vary depending on the radiation type and spectrum, which vary with depth in water [1-4]. If those e...
متن کاملMonte Carlo calculations of correction factors for plane-parallel ionization chambers in clinical electron dosimetry.
Recent standard dosimetry protocols recommend that plane-parallel ionization chambers be used in the measurements of depth-dose distributions or the calibration of low-energy electron beams with beam quality R50 <4 g/cm2. In electron dosimetry protocols with the plane-parallel chambers, the wall correction factor, Pwall, in water is assumed to be unity and the replacement correction factor, Pre...
متن کاملMeasurements of output factors using different ionization chambers and build up caps
Background: The aim of this work was to study the output factors for Linac using different ionization chambers and build up caps. Materials and Methods: Output factors were measured for open square fields (3 × 3 cm to 40 × 40 cm) defined by collimator jaws for 6 and 15 MV photon beams from a Varian Clinac 2100C accelerator were measured. The measurements in air were performed using Com...
متن کامل