Comparison of Safety Margin Generation Concepts in Image Guided Radiotherapy to Account for Daily Head and Neck Pose Variations

نویسندگان

  • Markus Stoll
  • Eva Maria Stoiber
  • Sarah Grimm
  • Jürgen Debus
  • Rolf Bendl
  • Kristina Giske
چکیده

PURPOSE Intensity modulated radiation therapy (IMRT) of head and neck tumors allows a precise conformation of the high-dose region to clinical target volumes (CTVs) while respecting dose limits to organs a risk (OARs). Accurate patient setup reduces translational and rotational deviations between therapy planning and therapy delivery days. However, uncertainties in the shape of the CTV and OARs due to e.g. small pose variations in the highly deformable anatomy of the head and neck region can still compromise the dose conformation. Routinely applied safety margins around the CTV cause higher dose deposition in adjacent healthy tissue and should be kept as small as possible. MATERIALS AND METHODS In this work we evaluate and compare three approaches for margin generation 1) a clinically used approach with a constant isotropic 3 mm margin, 2) a previously proposed approach adopting a spatial model of the patient and 3) a newly developed approach adopting a biomechanical model of the patient. All approaches are retrospectively evaluated using a large patient cohort of over 500 fraction control CT images with heterogeneous pose changes. Automatic methods for finding landmark positions in the control CT images are combined with a patient specific biomechanical finite element model to evaluate the CTV deformation. RESULTS The applied methods for deformation modeling show that the pose changes cause deformations in the target region with a mean motion magnitude of 1.80 mm. We found that the CTV size can be reduced by both variable margin approaches by 15.6% and 13.3% respectively, while maintaining the CTV coverage. With approach 3 an increase of target coverage was obtained. CONCLUSION Variable margins increase target coverage, reduce risk to OARs and improve healthy tissue sparing at the same time.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Utilization of Electronic Portal Imaging Device (EPID) For Setup Verification and Determination of Setup Margin in Head and Neck Radiation Therapy

Introduction: Radiation therapy involves a multistep procedure; therefore, the error in patient set up is an inherent part of the treatment. Main purpose of this study was to determine the clinical target volume (CTV) to planning target volume (PTV) in head and neck cancer patients. Material and Methods: A total of 15 patients who had daily p...

متن کامل

Image-guided prostate radiotherapy: analysis of inter- fractional setup errors

Introduction: The accuracy of the patient setup and tumor location are major factors that determine the efficacy of radiotherapy treatment planning. In the prostate radiotherapy, reproducibility of the prostate location for each treatment fraction is problematic owing to varying filling of the rectum and bladder. According to this, the aim of this study was to measure the inte...

متن کامل

Comparison of daily versus nondaily image-guided radiotherapy protocols for patients treated with intensity-modulated radiotherapy for head and neck cancer.

BACKGROUND The purpose of this study was to determine the feasibility of nondaily image-guided radiotherapy (RT) strategies with intensity-modulated radiotherapy (IMRT) for head and neck cancer. METHODS Alignment data was analyzed from 103 consecutive patients treated by IMRT for head and neck cancer who had undergone daily imaging with onboard mega-voltage CT (MVCT), resulting in 3275 images...

متن کامل

Drug repositioning from bench to bedside: tumour remission by the antihelmintic drug mebendazole in refractory metastatic colon cancer.

Chen AM , Farwell DG , Luu Q , Donald PJ , Perks J , Purdy J . [20] Evaluation of the planning target volume in the treatment of head and neck cancer with intensity-modulated radiotherapy: What is the appropriate expansion margin in the setting of daily image guidance? Int J Radiat Oncol Biol Phys 2011 ; 81 : 943 – 9 . Van Herk M , Remeijer P , Rasch C , Lebesque JV . The [21] probability of co...

متن کامل

A novel setup approach for helical tomotherapy in head and neck cancer: A case report

Head and neck cancers that are associated with high-risk factors have a poor prognosis. In such patients, post-operative radiochemotherapy is mandatory. The present study describes the case of a 71-year-old high-risk head and neck cancer patient who was not able to tolerate the supine position for the radiotherapy setup. A lateral immobilization with a head mask and a vacuum cushion was perform...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -