Portable peak flow meters: physical characteristics, influence of temperature, altitude, and humidity.
نویسندگان
چکیده
Little is known about the linearity of portable peak flow meters, or about physical gas factors affecting peak expiratory flow (PEF) readings. We therefore tested five portable peak flow meters of three types in an altitude chamber (sea level to 5,500 m) and in a climate chamber at sea level (7-37 degrees C) to determine the influence of the physical conditions of the gas on the reading of the meters. The nonlinear response of the variable orifice meters was confirmed and, when this was corrected for, the readings of these meters were found to be significantly reduced by higher altitude and lower temperature. The readings from a turbine type of peak flow meter were not affected by altitude but were reduced at low temperature. A mathematical model for the variable orifice meters could correct for both their nonlinear behaviour and the effect of gas density (altitude, temperature and humidity). The model showed that correction is not necessary for the differences in gas conditions between calibration and taking of measurements under normal laboratory conditions. All the meters tested had impedances higher than recommended (0.05 kPa.l-1.s) and this may influence PEF at high flows. The mean uncorrected PEF of six healthy subjects when measured with a Mini Wright peak flow meter at sea level and at 3,000 m fell by 5%, but the mean corrected PEF increased by 12%. This increase in PEF was about 60% of that predicted for fully density-dependent flow and agreed with the findings of other similar studies.(ABSTRACT TRUNCATED AT 250 WORDS)
منابع مشابه
Nasal peak inspiratory flow at altitudeFor
Nasal peak inspiratory flow at altitude. P.W. Barry, N.P. Mason, J-P. Richalet. #ERS Journals Ltd 2002. ABSTRACT: The present study investigated whether there are changes in nasal peak inspiratory flow (NPIF) during hypobaric hypoxia under controlled environmental conditions. During operation Everest III (COMEX 997), eight subjects ascended to a simulated altitude of 8,848 m in a hypobaric cham...
متن کاملAssessment of Storage and Temperature on Egg Physical Qualities for Peak Production in Hyline Chickens
The aim of the study was to evaluate the effect of storage and temperature on egg physical quality in Hyline chickens line. A total of 150 eggs from College of Natural Resources farm were sampled for the present experiment. About 70 eggs each were stored in home refrigerator (temperature, 7.46±0.23 ˚C; relative humidity, 24.80±0.05%) and room temperature (temperature, 22.98±1.12 ˚C; relative hu...
متن کاملModelling bryophytes distribution pattern using environmental parameters of Iran in Geographical Information Systems (GIS): a case study of three genera Tortula, Grimmia and Bryum (Bryophyta)
In the present study, a modelling approach based on Geographical Information Systems (GIS) analysis is presented with the aim of identifying the influence of environmental parameters on three genera, namely, Tortula, Grimmia and Bryum as representatives of Iranian bryoflora. By using ArcGIS Desktop, we produced a model for environmental variables include altitude, precipitation, temperature and...
متن کاملEffect of air pollution on lung function in schoolchildren in Rio de Janeiro, Brazil.
OBJECTIVE To assess the association between daily exposure to air pollution and lung function in school children. METHODS Panel study with a random sample of 118 students (between 6 and 15 years of age), enrolled in a public school of the city of Rio de Janeiro, state of Rio de Janeiro, and living within 2 km of the study site. Data on students' characteristics were obtained with a questionna...
متن کاملComparison of five portable peak flow meters
OBJECTIVE To compare the measurements of spirometric peak expiratory flow (PEF) from five different PEF meters and to determine if their values are in agreement. Inaccurate equipment may result in incorrect diagnoses of asthma and inappropriate treatments. METHODS Sixty-eight healthy, sedentary and insufficiently active subjects, aged from 19 to 40 years, performed PEF measurements using Air ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The European respiratory journal
دوره 7 5 شماره
صفحات -
تاریخ انتشار 1994