Quasi-steady-state displacement response of whole human cadaveric knees in a MRI scanner.
نویسندگان
چکیده
It is important to determine the three-dimensional nonuniform deformation of articular cartilage in its native environment. A new magnetic resonance imaging (MRI)-based technique (cartilage deformation by tag registration (CDTR)) has been developed, which can determine such deformations provided that the compressive load-displacement response of the knee reaches a quasi-steady state during cyclic loading. The objectives of this study were (1) to design and construct an apparatus to cyclically compress human cadaveric knees to physiological loads in a MRI scanner, (2) to determine the number of load cycles required to reach a quasi-steady-state load-displacement response for cyclic loading of human cadaveric knees, and (3) to collect sample MR images of undeformed and deformed states of tibiofemoral cartilage free of artifact while using the apparatus within a MRI scanner. An electropneumatic MRI-compatible apparatus was constructed to fit in a clinical MRI scanner, and a slope criterion was defined to indicate the point at which a quasi-steady-state load-displacement response, which would allow the use of CDTR, occurred during cyclic loading of a human knee. The average number of cycles required to reach a quasi-steady-state load-displacement response according to the slope criterion defined herein for three cadaveric knee joints was 356+/-69. This indicates that human knee joint specimens can be cyclically loaded such that deformation is repeatable according to MRI requirements of CDTR. Sample images of tibiofemoral cartilage were obtained for a single knee joint. These images demonstrate the usefulness of the apparatus in a MRI scanner. Thus the results of this study are a crucial step toward developing a MRI-based method to determine the deformations of articular cartilage in whole human cadaveric knees.
منابع مشابه
In situ deformation of cartilage in cyclically loaded tibiofemoral joints by displacement-encoded MRI.
OBJECTIVES Cartilage displacement and strain patterns were documented noninvasively in intact tibiofemoral joints in situ by magnetic resonance imaging (MRI). This study determined the number of compressive loading cycles required to precondition intact joints prior to imaging, the spatial distribution of displacements and strains in cartilage using displacement-encoded MRI, and the depth-depen...
متن کاملToward an MRI-based method to measure non-uniform cartilage deformation: an MRI-cyclic loading apparatus system and steady-state cyclic displacement of articular cartilage under compressive loading.
Recent magnetic resonance imaging (MRI) techniques have shown potential for measuring non-uniform deformations throughout the volume (i.e. three-dimensional (3D) deformations) in small orthopedic tissues such as articular cartilage. However, to analyze cartilage deformation using MRI techniques, a system is required which can construct images from multiple acquisitions of MRI signals from the c...
متن کاملEvaluation of seismic responses of earth dams in the steady-state seepage (a case study: Shamil Dam)
Considering the high seismic potential in most parts of Iran, the importance of studying the behavior of earth dams under earthquake loading, especially in the southern regions, is very important due to the number of these dams and seismicity of the Zagros mountain range. In recent years, many studies have been performed on the effects of earthquakes on earth dams, but these structures exhibit ...
متن کاملKnee cartilage topography, thickness, and contact areas from MRI: in-vitro calibration and in-vivo measurements.
OBJECTIVE This study assessed the three-dimensional accuracy of magnetic resonance imaging (MRI) for measuring articular surface topographies and cartilage thicknesses of human cadaveric knee joints, by comparison with the calibrated stereophotogrammetric (SPG) method. METHODS Six fresh frozen cadaveric knees and the knees of four volunteers were imaged with a three-dimensional spoiled gradie...
متن کاملFundamental Steady state Solution for the Transversely Isotropic Half Space
Response of a transversely isotropic 3-D half-space subjected to a surface time-harmonic excitation is presented in analytical form. The derivation of the fundamental solutions expressed in terms of displacements is based on the prefect series of displacement potential functions that have been obtained in the companion paper by the authors. First the governing equations are uncoupled in the cyl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of biomechanical engineering
دوره 131 8 شماره
صفحات -
تاریخ انتشار 2009