Fibrin Glue Reduces the Duration of Lymphatic Drainage after Lumpectomy and Level II or III Axillary Lymph Node Dissection for Breast Cancer: A Prospective Randomized Trial
نویسندگان
چکیده
This randomized prospective study investigated the effect of fibrin glue use on drainage duration and overall drain output after lumpectomy and axillary dissection in breast cancer patients. A total of 100 patients undergoing breast lumpectomy and axillary dissection were randomized to a fibrin glue group (N=50; glue sprayed onto the axillary dissection site) or a control group (N=50). Outcome measures were drainage duration, overall drain output, and incidence of seroma. Overall, the fibrin glue and control groups were similar in terms of drainage duration, overall drain output, and incidence of seroma. However, subgroup analysis showed that fibrin glue use resulted in a shorter drainage duration (3.5 vs. 4.7 days; p=0.0006) and overall drain output (196 vs. 278 mL; p=0.0255) in patients undergoing level II or III axillary dissection. Fibrin glue use reduced drainage duration and overall drain output in breast cancer patients undergoing a lumpectomy and level II or III axillary dissection.
منابع مشابه
Standardization of whole breast radiotherapy is required for safe omission of axillary lymph node dissection in breast cancer patients
Background: The purpose of this study was to assess the dose distribution and coverage of level Ⅰ-Ⅱ axillary lymph nodes during whole breast tangential field radiotherapy (RT) after breast-conserving surgery in patients with breast cancer. Materials and Methods: The level Ⅰ-Ⅱ axillary lymph node volumes were retrospectively contoured by a single radiation oncologist based on computed tomography...
متن کاملNew trends on fibrin glue in seroma after axillary lymphadenectomy for breast cancer.
BACKGROUND Axillary lymphadenectomy remains an integral part of breast cancer treatment, yet seroma formation occurs in 15-85% of cases. Among methods to reduce seroma magnitude and duration, fibrin glue has been proposed in several studies with controversial results. PATIENTS AND METHODS Ninety patients underwent quadrantectomy or mastectomy with level I/II axillary lymphadenectomy; a suctio...
متن کاملAxillary lymphadenectomy for breast cancer in elderly patients and fibrin glue
BACKGROUND Axillary lymphadenectomy or sentinel biopsy is integral part of breast cancer treatment, yet seroma formation occurs in 15-85% of cases. Among methods employed to reduce seroma magnitude and duration, fibrin glue has been proposed in numerous studies with controversial results. METHODS Thirty patients over 60 years underwent quadrantectomy or mastectomy with level I/II axillary lym...
متن کاملAxillary lymphadenectomy for breast cancer and fibrin glue.
BACKGROUND Axillary lymphadenectomy or sentinel biopsy is integral part of breast cancer treatment, yet seroma formation occurs in 15-85% of cases. Among methods employed to reduce seroma magnitude and duration, fibrin glue has been proposed in numerous studies with controversial results. METHODS Eighty patients underwent quadrantectomy or mastectomy with level I/II axillary lymphadenectomy; ...
متن کاملSentinel lymph node biopsy correctly predicts regional lymph node recurrence in trunk malignant melanoma with multiple drainage basins
We report a young male with an initial excisional biopsy report of melanoma of the lower back, referred to our hospital for complete excision and sentinel lymph node (SLN) biopsy. Four peritumoral intradermal Tc-99m phytate injection was performed and SLNs were detected in both axillary and right inguinal regions. On the biopsy only the right axillary SLN was metastatic leading to right axilla...
متن کامل