Percutaneous renal biopsy utilizing real time, ultrasonic guidance and a semiautomated biopsy device.
نویسندگان
چکیده
Percutaneous renal biopsy is a fundamental diagnostic technique in clinical nephrology. Since its introduction in 1951 [1], there have been several descriptions of the technique with refinements of the procedure, more recently employing ultrasonic guidance [2—101. The technique described in this paper is a biopsy method employing real-time ultrasonic guidance and a semiautomated, spring-loaded biopsy needle.
منابع مشابه
A prospective audit of complications in 100 consecutive pediatric percutaneous renal biopsies done under real-time ultrasound guidance
Despite being a common procedure, percutaneous renal biopsy (PRB) carries the potential for complications. The British Association of Paediatric Nephrologist (BAPN) has published standards for pediatric PRB. As Indian data are scarce, we conducted a prospective audit of 100 consecutive pediatric renal biopsies (60% males) under real-time ultrasound guidance. Nephrotic syndrome was the most comm...
متن کاملSafety and Adequacy of Percutaneous Biopsies in Pediatric Orthotopic Kidney Transplantation
BACKGROUND The gold standard for investigating the cause of renal graft dysfunction is renal biopsy. However, as this procedure is invasive and has inherent risks, its safety must be established. OBJECTIVE To determine the safety of percutaneous renal biopsy in pediatric orthotopic renal transplantation. METHODS Percutaneous renal biopsies performed on pediatric orthotopic renal transplants...
متن کاملUSG assisted and USG guided percutaneous renal biopsy at Nepal Medical College Teaching Hospital: a three and half years study.
A prospective study was carried out from 2009 to 2013 in the Department of Radiology and Imaging of Nepal Medical College and Teaching Hospital, Attarkhel, Jorpati, Kathmandu, Nepal, in which a total of 75 patients underwent percutaneous renal biopsy with a 16 or 18 gauge needles. This was done blindly by marking a site on the skin, or, whenever there was difficulty with the blind procedure, by...
متن کاملCT guided percutaneous renal biopsy versus ultrasound guided for obtaining adequate tissue.
OBJECTIVE To study the diagnostic yield of specimen obtained by percutaneous renal biopsy (PRB) under CT guidance and Ultrasound (US) guidance. METHODS This study was conducted at the department of Nephrology at Liaquat National Hospital and Dr. Ziauddin Hospital, Karachi. Renal biopsy specimens obtained between January 2007 and September 2009 were studied for number of glomeruli obtained. In...
متن کاملReal-time ultrasound-guided percutaneous renal biopsy with needle guide by nephrologists decreases post-biopsy complications
BACKGROUND Percutaneous renal biopsy (PRB) can result in serious complications. The study is aimed to compare the biopsy yield and complications rate of the real-time ultrasonagram (USG)-guided PRB and needle tracking with and without needle guide in two different study periods. METHODS We compared the yield and complications of 2138 kidney biopsies performed in two different periods, 1510 bi...