Bundles of Spider Silk, Braided into Sutures, Resist Basic Cyclic Tests: Potential Use for Flexor Tendon Repair

نویسندگان

  • Kathleen Hennecke
  • Joern Redeker
  • Joern W. Kuhbier
  • Sarah Strauss
  • Christina Allmeling
  • Cornelia Kasper
  • Kerstin Reimers
  • Peter M. Vogt
چکیده

Repair success for injuries to the flexor tendon in the hand is often limited by the in vivo behaviour of the suture used for repair. Common problems associated with the choice of suture material include increased risk of infection, foreign body reactions, and inappropriate mechanical responses, particularly decreases in mechanical properties over time. Improved suture materials are therefore needed. As high-performance materials with excellent tensile strength, spider silk fibres are an extremely promising candidate for use in surgical sutures. However, the mechanical behaviour of sutures comprised of individual silk fibres braided together has not been thoroughly investigated. In the present study, we characterise the maximum tensile strength, stress, strain, elastic modulus, and fatigue response of silk sutures produced using different braiding methods to investigate the influence of braiding on the tensile properties of the sutures. The mechanical properties of conventional surgical sutures are also characterised to assess whether silk offers any advantages over conventional suture materials. The results demonstrate that braiding single spider silk fibres together produces strong sutures with excellent fatigue behaviour; the braided silk sutures exhibited tensile strengths comparable to those of conventional sutures and no loss of strength over 1000 fatigue cycles. In addition, the braiding technique had a significant influence on the tensile properties of the braided silk sutures. These results suggest that braided spider silk could be suitable for use as sutures in flexor tendon repair, providing similar tensile behaviour and improved fatigue properties compared with conventional suture materials.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cyclic testing of pullout sutures and micro-mitek suture anchors in flexor digitorum profundus tendon distal fixation.

PURPOSE Little data exist comparing the strength of traditional methods of fixation in a flexor digitorum profundus tendon with the use of a suture anchor. In vitro cyclic testing simulating a passive mobilization protocol was used to compare the repair of a flexor digitorum profundus tendon using a single micro-Mitek anchor (Mitek, Westwood, MA) or a modified Bunnell 2-strand pullout technique...

متن کامل

Mechanical Properties of Polyglycolide-trimethylene Carbonate and Polydioxanone Monofilament Sutures in Vivo Used for Flexor Tendon Repair

INTRODUCTION Braided polyester suture materials have been commonly used for flexor tendon repair in the clinical setting. However, knotted braided polyester lost approximately 50% of its tensile strength according to a study by Trail et al.(1) Accordingly, 4 or 5 throws are needed to prevent slippage for a secure knot, which may result in stitch granuloma. The use of absorbable sutures avoids p...

متن کامل

Comparison of mechanical properties of polyvinylidene fluoride and polypropylene monofilament sutures used for flexor tendon repair.

We performed an experimental study to evaluate the mechanical properties of polyvinylidene fluoride sutures and to compare their use with that of standard polypropylene sutures for the circumferential, epitendinous suture of a flexor tendon repair. Polyvinylidene fluoride sutures had a smaller suture diameter, a greater knot pull strength and less delayed extension when under creep testing, tha...

متن کامل

A new modified Tsuge suture for flexor tendon repairs: the biomechanical analysis and clinical application

PURPOSE This study is to develop a new suturing technique for flexor tendon repair by modifying the extant Tsuge repair techniques and to use biomechanical analysis to compare the new method with four established repair techniques and evaluate its clinical efficacy in the repair of 47 flexor tendons in 22 patients. METHODS The biomechanical analysis relied on 50 flexor digitorum profundus ten...

متن کامل

Intrasynovial flexor tendon repair: a biomechanical study of variations in suture application in human cadavera.

To improve the functional outcomes of intrasynovial tendon suture, prior experiments evaluated individual technical modifications used in the repair process. Few studies, however, have assessed the combinatorial effects of those suture modifications in an integrated biomechanical manner, including a sample size sufficient to make definitive observations on repair technique. Two hundred fifty-si...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2013