Self-localization of laser induced tumour coagulation limited by heat diffusion through active tissue.

نویسندگان

  • B Y Datsko
  • V V Gafiychuk
  • I A Lubashevsky
  • A V Priezzhev
چکیده

We analyse necrosis growth due to thermal coagulation induced by laser light absorption and limited by heat diffusion into the surrounding live tissue. The tissue is assumed to contain a tumour in the undamaged tissue where the blood perfusion rate does not change during the action. By contrast, normal tissue responds strongly to an increase in the tissue temperature and the blood perfusion rate can grow by tenfold. We study in detail necrosis formation under conditions typical of a real course of thermal therapy treatment. The duration of the treatment is about 5 minutes when a necrosis domain of about 1 cm or above is formed. In particular, if the tumour size is sufficiently large, i.e. it exceeds 1 cm, and the tissue response is not too delayed, i.e. the delay time does not exceed 1 min, then there are conditions under which the relative volume of the damaged normal tissue is small in comparison with the tumour volume after the tumour is totally coagulated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Laser Induced Heat Diffusion Limited Tissue Coagulation: Problem and General Properties

Previously we have developed a free boundary model for local thermal coagulation induced by laser light absorption when the tissue region affected directly by laser light is sufficiently small and heat diffusion into the surrounding tissue governs the necrosis growth. In the present paper surveying the obtained results we state the point of view on the necrosis formation under these conditions ...

متن کامل

Analysis of the theory of thermal damage in biological tissues caused by Laser beam

Introduction: In laser surgery, the laser beam can evaporate and cut the tissue like a small surgical knife when the tissue temperature is heated to 100 degrees Celsius. a complete understanding of the distribution of damage in both pathologic tissue and surrounding tissue is necessary. Although the test is the most realistic solution for treating medical problems, for this rea...

متن کامل

Comparison of Soft Tissue Thermal Changes Induced by Three Types of Diode Lasers at 810, 940, and 980nm Wavelengths

Background and Aim: Diode laser is a great choice for soft tissue surgery. The diode laser is partially absorbed by hard dental tissues, making it safe for soft tissue surgery. This study aimed to compare the tissue thermal changes induced by three types of diode lasers at 810, 940, and 980nm wavelengths. Materials and Methods: In this in-vitro experimental study, using a diode laser device (c...

متن کامل

The effect of self-absorption correction using internal reference on determining heavy metals concentration by laser induced breakdown spectroscopy

The identification and concentration of heavy metals, which may be so harmful for the body, is determined by the method of calibration-free laser-induced breakdown spectroscopy using a special strategy. First, the plasma temperature is obtained using the Boltzmann plot. Then, a line with an inappreciable self-absorption is considered for each element as the reference. The modified intensities o...

متن کامل

Slow intramural heating with diffused laser light: A unique method for deep myocardial coagulation.

BACKGROUND Catheter ablation of postinfarction ventricular tachycardia (VT) may be limited by insufficient myocardial coagulation or excessive endocardial or epicardial damage. We propose that volumetric heating restricted to intramural sites may improve the outcome and safety of this procedure, especially if delivered at rates that enhance heat conduction and forestall adverse tissue changes. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of medical engineering & technology

دوره 30 6  شماره 

صفحات  -