Adenosine stress myocardial contrast echocardiography for the detection of coronary artery disease: a comparison with coronary angiography and cardiac magnetic resonance.
نویسندگان
چکیده
OBJECTIVES To evaluate the accuracy of adenosine myocardial contrast echocardiography (MCE) in diagnosing coronary artery disease (CAD). BACKGROUND Adenosine stress echocardiography is not routinely used in the assessment of CAD. Since ultrasound microbubble contrast agents enable improved wall motion analysis and simultaneous assessment of myocardial perfusion, we sought to evaluate the diagnostic performance of combined wall motion/perfusion imaging with adenosine MCE in patients with suspected CAD. We evaluated the accuracy of adenosine MCE in identifying 1) the presence of anatomic disease, as defined by X-ray angiography, and 2) the functional significance of CAD, as determined by high field-strength (3-T), multiparametric cardiac magnetic resonance (CMR) imaging. METHODS Sixty-five patients with suspected CAD were studied before angiography with MCE and CMR, at stress (140 μg/kg/min intravenous adenosine) and at rest. For MCE, 2-, 3- and 4-chamber long-axis images were acquired during intravenous sulfur hexafluoride infusion. For CMR, short-axis first-pass perfusion and delayed enhancement images were acquired following intravenous gadolinium-diethylenetriaminepentaacetic acid bolus injections (0.05 mmol/kg). Quantitative coronary angiography served as a reference standard for anatomic disease (significant CAD defined as ≥ 50% reference diameter in vessels with diameter ≥ 2 mm). RESULTS Compared with X-ray angiography, MCE provided diagnostic accuracy of 82%, sensitivity of 85%, and specificity of 76% for detecting significant coronary stenosis. Disease location was also identified with reasonable accuracy (diagnostic accuracy 81% for left anterior descending disease, 77% for left circumflex artery disease, and 84% for right coronary artery disease). With CMR as the reference standard for functional assessment, MCE provided diagnostic accuracy of 79%, sensitivity of 85%, and specificity of 74%. Interobserver agreement for MCE was 79% (95% confidence interval: 67% to 88%). CONCLUSIONS Adenosine MCE achieved favorable diagnostic performance in identifying the presence and functional significance of coronary stenosis. Adenosine MCE may be useful in the clinical setting for evaluating patients with suspected CAD.
منابع مشابه
Relationship between Late Gadolinium Enhancement Extent in Cardiac Magnetic Resonance Imaging and Severity of Coronary Artery Disease in Old Myocardial Infarction
Purpose: To assess the relationship between the severity of coronary arteries involvement and the extent and pattern of myocardial scars in Cardiac Magnetic Resonance of patients with history of remote myocardial infarction. Materials and Methods: The Cardiac Magnetic Resonance images of sixty patients with history of remote ST segment or non-ST segment elevation myocardial infarction were ...
متن کاملMyocardial perfusion scan accuracy in detection of coronary artery disease - Comparison with exercise stress test [Persian]
Introduction: In patients with coronary artery disease (CAD) noninvasive evaluation for detection of ischemia is important to avoid invasive interventions like angiography. Exercise stress test is conventionally the first study used in evaluation of CAD. Considering the noninvasive nature of the myocardial perfusion scan, we decided to compare its accuracy with stress test. Methods: Patie...
متن کاملMultiple myocardial bridge in a 59 year-old woman
Introduction: Myocardial bridging is a congenital condition in which a segment of a major epicardial coronary artery has an intra myocardial route. Myocardial bridging is usually confined to a single vessel and is typically the mid segment of the left anterior descending artery. Bridging may be associated with chest pain, myocardial infarction, and sudden cardiac death, or usually asymptomati...
متن کاملDetection of Cardiac Artery Disease by Using the DCAD (b) Module
Introduction: In patients with cardiac artery disease, a myocardial perfusion scan, which is a non-invasive method, is utilized. This study is conducted to develop an advantageous software applicable to quantitative myocardial SPECT perfusion. Material and Methods: Each cross-section of the left ventricle was segmented by applying a fuzzy clustering method. After obtaining the myocardial skelet...
متن کاملComparison of dobutamine stress magnetic resonance, adenosine stress magnetic resonance, and adenosine stress magnetic resonance perfusion.
BACKGROUND Dobutamine stress MR (DSMR) is highly accurate for the detection of inducible wall motion abnormalities (IWMAs). Adenosine has a more favorable safety profile and is well established for the assessment of myocardial perfusion. We evaluated the diagnostic value of IWMAs during dobutamine and adenosine stress MR and adenosine MR perfusion compared with invasive coronary angiography. ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- JACC. Cardiovascular imaging
دوره 3 9 شماره
صفحات -
تاریخ انتشار 2010