Incorporation of a laser range scanner into image-guided liver surgery: surface acquisition, registration, and tracking.

نویسندگان

  • David M Cash
  • Tuhin K Sinha
  • William C Chapman
  • Hiromi Terawaki
  • Benoit M Dawant
  • Robert L Galloway
  • Michael I Miga
چکیده

As image guided surgical procedures become increasingly diverse, there will be more scenarios where point-based fiducials cannot be accurately localized for registration and rigid body assumptions no longer hold. As a result, procedures will rely more frequently on anatomical surfaces for the basis of image alignment and will require intraoperative geometric data to measure and compensate for tissue deformation in the organ. In this paper we outline methods for which a laser range scanner may be used to accomplish these tasks intraoperatively. A laser range scanner based on the optical principle of triangulation acquires a dense set of three-dimensional point data in a very rapid, noncontact fashion. Phantom studies were performed to test the ability to link range scan data with traditional modes of image-guided surgery data through localization, registration, and tracking in physical space. The experiments demonstrate that the scanner is capable of localizing point-based fiducials to within 0.2 mm and capable of achieving point and surface based registrations with target registration error of less than 2.0 mm. Tracking points in physical space with the range scanning system yields an error of 1.4 +/- 0.8 mm. Surface deformation studies were performed with the range scanner in order to determine if this device was capable of acquiring enough information for compensation algorithms. In the surface deformation studies, the range scanner was able to detect changes in surface shape due to deformation comparable to those detected by tomographic image studies. Use of the range scanner has been approved for clinical trials, and an initial intraoperative range scan experiment is presented. In all of these studies, the primary source of error in range scan data is deterministically related to the position and orientation of the surface within the scanner's field of view. However, this systematic error can be corrected, allowing the range scanner to provide a rapid, robust method of acquiring anatomical surfaces intraoperatively.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fast, accurate surface acquisition using a laser range scanner for image-guided liver surgery

Many image guided surgical (IGS) procedures use surface representations of anatomical features to provide a registration between physical space and image space. While anatomical fiducial registration techniques can often be compromised by soft tissue deformation, laser-scanning systems offer a non-contact method for accurately resolving geometric surfaces. This digitization approach is particul...

متن کامل

Incorporation of a laser range scanner into an image-guided surgical system

Laser range scanners provide rapid and accurate non-contact methods for acquiring three-dimensional surface data, offering many advantages over other techniques currently available during surgery. The range scanner was incorporated into our image-guided surgery system to augment registration and deformation compensation. A rigid body, embedded with infrared diodes, was attached to the scanner f...

متن کامل

Textured laser range scanning and registration of the cortical surface

A novel method for intra-operative data acquisition using a laser range scanner is presented for applications in model-updated image-guided surgery. The scanner produces a point cloud containing true-color encoded range data of its field-of-view. This allows characterization of intra-operative conditions using both intensity and geometry information. Furthermore, a rigid-body registration algor...

متن کامل

Cortical Shift Tracking Using a Laser Range Scanner and Deformable Registration Methods

A novel brain shift tracking protocol is introduced in this paper which utilizes laser range scan (LRS) data and 2D deformable image registration. This protocol builds on previous efforts to incorporate intra-operative LRS data into a model-updated image guided surgery paradigm for brain shift compensation. The shift tracking method employs the use of a LRS system capable of capturing textures ...

متن کامل

Robust surface registration using salient anatomical features for image-guided liver surgery: algorithm and validation.

A successful surface-based image-to-physical space registration in image-guided liver surgery (IGLS) is critical to provide reliable guidance information to surgeons and pertinent surface displacement data for use in deformation correction algorithms. The current protocol used to perform the image-to-physical space registration involves an initial pose estimation provided by a point based regis...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 30 7  شماره 

صفحات  -

تاریخ انتشار 2003