Final design of the beam source for the MITICA injector.

نویسندگان

  • D Marcuzzi
  • P Agostinetti
  • M Dalla Palma
  • M De Muri
  • G Chitarin
  • G Gambetta
  • N Marconato
  • R Pasqualotto
  • M Pavei
  • N Pilan
  • A Rizzolo
  • G Serianni
  • V Toigo
  • L Trevisan
  • M Visentin
  • P Zaccaria
  • M Zaupa
  • D Boilson
  • J Graceffa
  • R S Hemsworth
  • C H Choi
  • M Marti
  • K Roux
  • M J Singh
  • A Masiello
  • M Froeschle
  • B Heinemann
  • R Nocentini
  • R Riedl
  • H Tobari
  • H P L de Esch
  • V N Muvvala
چکیده

The megavolt ITER injector and concept advancement experiment is the prototype and the test bed of the ITER heating and current drive neutral beam injectors, currently in the final design phase, in view of the installation in Padova Research on Injector Megavolt Accelerated facility in Padova, Italy. The beam source is the key component of the system, as its goal is the generation of the 1 MeV accelerated beam of deuterium or hydrogen negative ions. This paper presents the highlights of the latest developments for the finalization of the MITICA beam source design, together with a description of the most recent analyses and R&D activities carried out in support of the design.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radiation safety at the PRIMA facility: a review of shielding solutions and personnel dose assessment

The Neutral Beam Test Facility (NBTF), also called PRIMA (acronym for Padova Research on ITER Megavolt Accelerator) consists of two separate development test beds currently under construction in Padua (Italy): the ion source test facility, named SPIDER (Source for Production of Ion of Deuterium Extracted from Rf plasma) and the megavolt test facility, called MITICA (acronym for Megavolt ITER In...

متن کامل

طراحی و ساخت پیش تزریق‌گر الکترون چشمه نور ایران

Every synchrotron accelerator requires a pre-injector for primary injection of the electrons into the booster ring. The Iranian Light Source Facility (ILSF) pre-injector is a 150 MeV S-band linear accelerator with a thermionic cathode RF gun. The design of the pre-injector lattice and its beam dynamics calculation results together with the design of RF gun, alpha magnet, quadrupole magnets and ...

متن کامل

Off-normal and failure condition analysis of the MITICA negative-ion accelerator.

The negative-ion accelerator for the MITICA neutral beam injector has been designed and optimized in order to reduce the thermo-mechanical stresses in all components below limits compatible with the required fatigue life. However, deviation from the expected beam performances can be caused by "off-normal" operating conditions of the accelerator. The purpose of the present work is to identify an...

متن کامل

Preliminary Design Concepts for the Control and Data Acquisition Systems of the Iter Neutral Beam Injector and Associated Test Facility

ITER is a joint international research and development project aiming to demonstrate the scientific and technical feasibility of fusion power. The ITER Neutral Beam Injector (negative H or D ion source, 1MV acceleration voltage, 40A ion current, 16.5MW beam power, 1 hour continuous operation) is a major and innovative component of ITER and will be supported by a dedicated Test Facility. The neu...

متن کامل

Overview of diagnostics on ITER neutral beam test facility

ITER operation relies on heating neutral beam injectors (HNB) based on negative ion deuterium beams accelerated at 1 MeV, with up to one hour 17 MW power, uniform intensity and low divergence. A neutral beam test facility is being built at Consorzio RFX to demonstrate the feasibility of a prototype injector with such demanding specifications and to optimize its performances. It comprises SPIDER...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Review of scientific instruments

دوره 87 2  شماره 

صفحات  -

تاریخ انتشار 2016