Laboratory test of a visual sputum suctioning system.

نویسندگان

  • Jingjing Lv
  • Jingxing Wu
  • Rui Guo
  • Xun Liu
  • Bingbing Yan
  • Huisheng Deng
چکیده

BACKGROUND Conventional sputum suctioning is a routine clinical practice, but complications may arise from the blind manipulation of the catheter. Recently, a visual sputum suctioning system (VSSS) was developed, and we tested this new system in a laboratory setting. METHODS We used coagulant concentrations of 1.5% and 3.0% to simulate mucus and sputum. Conventional single-lumen and triple-lumen catheters were inserted separately into a beaker for sputum suctioning (15 s, 200 mm Hg). A micro-imaging fiber was integrated into the triple-lumen catheter to create the VSSS. The single-lumen catheter and the VSSS were inserted separately into the mouth cavity, the nasal cavity, the tracheostomy tube, and the endotracheal tube of a human analog model for further comparisons. RESULTS As the suction channel of the triple-lumen catheter was reduced by 46.8%, the amount of simulant it suctioned was significantly less than that suctioned by the single-lumen catheter. However, under real-time guidance, the VSSS suctioned more simulant than the conventional single-lumen catheter in the human analog model. CONCLUSION Sputum suctioning with the VSSS was feasible. Because of its real-time imaging guidance, the efficiency of the VSSS procedure was greater than that of the conventional single-lumen catheter. Therefore, this system may provide a new platform for sputum suctioning.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A novel visual sputum suctioning system is useful for endotracheal suctioning in a dog model.

OBJECTIVE This study is to test the effectiveness of fiber-optic-guided endotracheal suction catheter (visual sputum suctioning system or VSSS) in dog models. METHODS Dog sputum models were established by administering dimethoate emulsifiable. Twenty-seven intubated dogs were equally randomized into three groups of conventional suctioning (CS) group, VSSS with no supplemental oxygen (VSSS) gr...

متن کامل

Evaluation of blind nasotracheal suctioning and non-bronchoscopic mini-bronchoalveolar lavage in critically ill patients with infectious pneumonia: a preliminary study.

BACKGROUND We evaluated the diagnostic performance and safety of combined blind nasotracheal suctioning and non-bronchoscopic mini-bronchoalveolar lavage (mini-BAL) to obtain respiratory secretion specimens from spontaneously breathing, non-intubated patients with infectious pneumonia in intensive care. METHODS Patients suspected of having infectious pneumonia were included prospectively. Thr...

متن کامل

A Comparison of the effect of open and closed endotracheal suctioning on hemodynamic status of patients in the ICU

Background: If not done properly, suction causes complications such as hypoxia, cardiac arrhythmias or even death. Suction is being used in most hospital wards. Closed Suction appears to have fewer side effects, although studies have reported dissimilar results. Aim: The aim of this study was to compare the effect of open (control) with closed (test) endotracheal suctioning on patients’ Hemodyn...

متن کامل

Effect of Suctioning of the Middle Ear Effusion on Hearing Condition Before Ventilation Tube Insertion

Abstract OME is a Common disease in children. over than 90% of children in preschool ages experienced this disease once at least. Despite medical therapy about 10% of the OME patients won't improved and these are the group of patients who referred to as chronic OME patients. Insertion of VT in TM is an accepted therapy for these patients and during surgery for insertion of VT, suctioning of mi...

متن کامل

مقایسه تاثیر دو روش ساکشن باز و بسته بر دیس ریتمی های قلبی بیماران تحت تهویه مکانیکی

Background: Nowadays, due to an increase in patients require intensive care, application of mechanical ventilation and endotracheal tube is necessary. In order to Keeping an open airway, endotracheal suctioning is necessary. Select the appropriate suction method can reduce the severe complications. The aim of this study is comparing the efficacy of open and closed suctioning on heart disrhythmi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Respiratory care

دوره 58 10  شماره 

صفحات  -

تاریخ انتشار 2013