Development of forearm impedance plethysmography for the minimally invasive monitoring of cardiac pumping function

نویسندگان

  • Jia-Jung Wang
  • Wei-Chih Hu
  • Tsiar Kao
  • Chun-Peng Liu
  • Shih-Kai Lin
چکیده

It is essential to continuously and non-invasively monitor the cardiac pumping function in clinical setting. Thus, the study aimed to explore a regional impedance phethysmographic method to assess the changes in stroke volume. To do this, we developed a plethysmographic device that was capable of delivering a single-frequency current with constant amplitude and of recording electrical impedance signals of biological tissue. The electrical impedance plethysmographic waveform form the lower arm was measured with the impedance plethysmographic device, and simultaneously the end-systolic and enddiastolic volumes of the left ventricle were obtained with a two-dimension echocardiographic system in fourteen healthy subjects before and immediately after a thirty-second breath-hold maneuver. For the 14 subjects, a linear correlation coefficient of 0.79 (p < 0.001) was obtained between the changes in peak amplitude of the forearm impedance waveform and the changes in stroke volume before and just after the breath-hold test. In addition, the changes in the mean area under the impedance curve and the change in stroke volume were also correlated linearly (r = 0.71, p < 0.005). In summary, the forearm impedance plethysmography may be employed to evaluate the beat-to-beat alteration in cardiac stroke volume, suggesting its potential for long-term monitoring cardiac pumping performance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bilateral C5 Palsy Following a Circumferential Surgery for Cervical Spondylotic Myelopathy: Case Report and Review (In press)

Background and Importance: The development of C5 root palsy is a well-known potential complication of cervical spine surgeries for the correction of cervical spondylotic myelopathy. It typically occurs unilaterally but on extremely rare occasions it might occur as a bilateral anomaly. The value of intraoperative neurophysiologic monitoring in detection of iatrogenic acute versus delayed onset C...

متن کامل

Respiratory Monitoring: Advantages of Inductive Plethysmography over Impedance Pneumography

Inductive plethysmography and impedance pneumography are two non-invasive technologies for measuring respiratory function. The following report describes the advantages of inductive plethysmography, which include greater accuracy and sensitivity; the ability to assess thoracoabdominal coordination; and the minimization of motion artifact. Together, these properties make inductive plethysmograph...

متن کامل

Non-invasive Optical Techniques for determination of blood Glucose levels: A Review Article

This article reviews the development of non-invasive optical techniques for determination of blood glucose concentrations in diabetic patients. Early diagnosis and daily management are essential for ensuring the healthy life of diabetic patients. The determination of blood glucose concentration with common devices involves the chemical analysis of blood samples, which are obtained by pricking t...

متن کامل

Limitations of electric impedance plethysmography.

Klectrie impedance plethysmography has been offered as a substitute for mechanical plethysmography and would be particularly suitable for regions in which the mechanical method cannot be applied. A comparative investigation of mechanical and impedance plethysmograms, taken simultaneously from a finger or a forearm, revealed that, while the normal pulsations were reproduced reasonably well, elec...

متن کامل

A System for Continuous Estimating and Monitoring Cardiac Output via Arterial Waveform Analysis

Background: Cardiac output (CO) is the total volume of blood pumped by the heart per minute and is a function of heart rate and stroke volume. CO is one of the most important parameters for monitoring cardiac function, estimating global oxygen delivery and understanding the causes of high blood pressure. Hence, measuring CO has always been a matter of interest to researchers and clinicians. Sev...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011