Immediate weight bearing of comminuted supracondylar femur fractures using locked plate fixation.
نویسندگان
چکیده
Comminuted supracondylar femur fractures (AO-OTA 33A3) are commonly treated with locked plates. Weight bearing is generally restricted for 6 to 12 weeks until radiologic evidence exists of sufficient callous to support weight bearing. Recent clinical studies have reported high nonunion rates with distal femur locked plates. In an attempt to induce beneficial motion across the fracture site, some studies have recommended earlier weight bearing. The purpose of the current study was to determine the biomechanical feasibility of an immediate weight-bearing rehabilitation protocol to encourage healing of distal femur fractures treated with lateral locked plate fixation.Sixteen fresh-frozen cadaveric femora were used for this study. A 2.5-cm supracondylar gap osteotomy was made. Ten-hole, 4.5-mm distal femur locking plates were used with a standardized screw configuration that maximized the working length. The specimens were placed in a servohydraulic testing machine and axially loaded (unidirectional) at 1 Hz for up to 200,000 cycles. Failure was defined as 1 cm of deformation of the construct. The staircase method was used to determine the fatigue limit of the construct. The fatigue limit was calculated to be 1329±106 N. No specimen failed through the non-locking diaphyseal screws. Plastic deformation, when present, occurred at the metaphyseal flare of the plate. The fatigue limit of the locked plate constructs equaled 1.9 times body weight for an average 70-kg patient over a simulated 10-week postoperative course. Given that distal femoral loads during gait have been estimated to be more than 2 times body weight, the data from this study do not support immediate full weight bearing.
منابع مشابه
Intramedullary nailing versus locked plate for treating supracondylar periprosthetic femur fractures.
The objective of this study was to compare retrograde intramedullary femoral nailing with supracondylar locked screw-plate fixation for the treatment of periprosthetic femur fractures following total knee arthroplasty. Time to union and full weight bearing were the primary study outcomes, with perioperative blood loss, need for transfusion, need for revision surgery, and infection being the sec...
متن کاملPolyaxial locking plate fixation in distal femur fractures: a biomechanical comparison.
OBJECTIVES Uniaxial, first-generation locking plates have become increasingly popular for fixation of supracondylar femur fractures. Polyaxial plates are currently available, which allow for variable-angle screw insertion; however, the biomechanical integrity of these new locking constructs is yet unproven. This study compares the mechanical stability of a conventional locking plate with that o...
متن کاملThe use of tibial Less Invasive Stabilization System (LISS) plate [AO-ASIF] for the treatment of paediatric supracondylar fracture of femur: a case report
Paediatric supracondylar fractures of the femur are not common. The treatment options depend on the age of child, the site of the fracture, the pattern of injury and the surgeon's preference. We report a case of an 11-year old boy who sustained a comminuted displaced supracondylar fracture of the femur and was treated with indirect reduction and internal fixation with the Less Invasive Stabiliz...
متن کاملOutcomes of Surgical Management of Supracondylar Periprosthetic Femur Fractures.
BACKGROUND Fracture location is an important consideration in managing supracondylar periprosthetic femur fractures. The outcomes of locked plating and intramedullary (IM) nail fixation were therefore compared based on fracture location, being above or at/below the total knee arthroplasty (TKA) flange. METHODS Fifty-seven patients were identified from surgical records as being treated for sup...
متن کاملDoes locked plating of periprosthetic supracondylar femur fractures promote bone healing by callus formation? Two cases with opposite outcomes.
Contemporary locking plates promote biological fixation through indirect reduction techniques and by elevating the plate from the bone. They have improved fixation strength in osteoporotic bone. Periarticular locking plates are rapidly being adopted for bridge plating of periprosthetic femur fractures. When these plates are used for indirect reduction and bridge plating osteosynthesis, fracture...