Spectrum Binning Approach for Multi-Material Beam Hardening Correction (MMBHC) in CT

نویسندگان

  • Qiao Yang
  • Meng Wu
  • Nicole Maass
  • Andreas K. Maier
  • Joachim Hornegger
  • Rebecca Fahrig
چکیده

In CT, the nonlinear attenuation characteristics of polychromatic X-rays cause beam hardening artifacts in the reconstructed images. When datasets contain multiple materials in the field of scan, the performance of state-of-the-art beam hardening correction approaches is limited by high computational load and reduced correction efficiency. An image based multi-material beam hardening correction (MMBHC) method is introduced by conserving original reconstruction attenuation in a material density map, and obtaining beam harding artifacts by polychromatic forward projecting of the original CT images. By decomposing the attenuation coefficient into photoelectric and Compton scattering components, the spectrum can be parameterized and presented with several energy bins. In this paper, the MMBHC algorithm is accelerated by using a proposed spectrum binning (SB) method to reduce the required prior knowledge from full spectrum to three energy bins. The approach has a significant computational time reduction by use of material number independent forward projection and parameterized energy spectrum with fewer bins. Moreover, representing the spectrum with a few parameters instead of optimizing full spectrum increase the stability of the MMBHC process. The algorithm has been evaluated with a simulated phantom on 3D cone beam geometry. In comparison to correction results with full spectrum information, the results with optimized three bins spectrum shows comparable artifact reduction efficiency while providing significant reduction on computational time.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multi-Material Beam Hardening Correction(MMBHC) in Computed Tomography

In computed tomography (CT), the nonlinear attenuation characteristics of polychromatic X-rays cause beam hardening artifacts in the reconstructed images. State-of-theart methods to correct the beam hardening effect are mostly single material precorrections (e.g. water-precorrection), which are far less efficient when more than one material is present in the field of measurement. The use of tho...

متن کامل

Evaluation of Spectrum Mismatching using Spectrum Binning Approach for Statistical Polychromatic Reconstruction in CT

In CT, the nonlinear attenuation characteristics of polychromatic X-rays cause beam hardening artifacts in the reconstructed images. Statistical algorithms can effectively correct beam hardening artifacts while providing the benefit of noise reduction. In practice, a big challenge for CT is the difficulty at acquiring accurate energy spectrum information, which hinders the efficiency of beam ha...

متن کامل

Referenceless Beam Hardening Correction in 3D Computed Tomography Images of Multi-Material Objects

We propose a new method to reduce the effects of non-linearities such as beam hardening in Computed Tomography (CT) images. Due to the polychromatic characteristics of X-ray sources the ratio of attenuated and incoming intensity is not exactly exponential with the material thickness. Within CT images this leads to artifacts like cupping, streaks and blurring. Especially in multi-material object...

متن کامل

Iterative correction of beam hardening artifacts in CT.

PURPOSE To reduce beam hardening artifacts in CT in case of an unknown x-ray spectrum and unknown material properties. METHODS The authors assume that the object can be segmented into a few materials with different attenuation coefficients, and parameterize the spectrum using a small number of energy bins. The corresponding unknown spectrum parameters and material attenuation values are estim...

متن کامل

Beam hardening correction and its influence on the measurement accuracy and repeatability for CT dimensional metrology applications

The beam hardening effect is one of the major artifacts of X-ray computed tomography. It not only complicates medical inspection and material analysis, but also influences the accuracy and repeatability of dimensional measurements. Therefore, many efforts have been devoted to develop beam hardening correction methods since the early 1970s. In practice, the combination of hardware filters (pre-f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014