On the Perturbation Correction Factor pcav of the Markus Parallel-Plate Ion Chamber in Clinical Electron Beams

نویسندگان

  • Philip von Voigts-Rhetz
  • Hilke Vorwerk
  • Klemens Zink
چکیده

Purpose: All present dosimetry protocols recommend well-guarded parallelplate ion chambers for electron dosimetry. For the guard-less Markus chamber, an energy dependent fluence perturbation correction pcav is given. This perturbation correction was experimentally determined by van der Plaetsen by comparison of the read-out of a Markus and a NACP chamber, which was assumed to be “perturbation-free”. Aim of the present study is a Monte Carlo based reiteration of this experiment. Methods: Detailed models of four parallel-plate chambers (Roos, Markus, NACP and Advanced Markus) were designed using the Monte Carlo code EGSnrc and placed in a water phantom. For all chambers, the dose to the active volume filled with low density water was calculated for 13 clinical electron spectra (E0 = 6 21 MeV) and three energies of an Electra linear accelerator at the depth of maximum and at the reference depth under reference conditions. In all cases, the chamber’s reference point was positioned at the depth of measurement. Moreover, the dose to water DW was calculated in a small water voxel positioned at the same depth. Results: The calculated dose ratio DNACP/DMarkus, which according to van der Plaetsen reflects the fluence perturbation correction of the Markus chamber, deviates less from unity than the values given by van der Plaetsen, but exhibits similar energy dependence. The same holds for the dose ratios of the other well-guarded chambers. But, in comparison to water, the Markus chamber reveals the smallest overall perturbation correction which is nearly energy independent at both investigated depths. Conclusion: The simulations principally confirm the energy dependence of the dose ratio DNACP/DMarkus as published by van der Plaetsen. But, as shown by our simulations of the ratio DW/DMarkus, the conclusion drawn in all dosimetry protocols is questionable: in contrast to How to cite this paper: von Voigts-Rhetz, P., Vorwerk, H. and Zink, K. (2017) On the Perturbation Correction Factor pcav of the Markus Parallel-Plate Ion Chamber in Clinical Electron Beams. International Journal of Medical Physics, Clinical Engineering and Radiation Oncology, 6, 150-161. https://doi.org/10.4236/ijmpcero.2017.62014 Received: January 30, 2017 Accepted: May 20, 2017 Published: May 23, 2017 Copyright © 2017 by authors and Scientific Research Publishing Inc. This work is licensed under the Creative Commons Attribution International License (CC BY 4.0). http://creativecommons.org/licenses/by/4.0/ Open Access P. von Voigts-Rhetz et al. 151 all well-guarded chambers, the guard-less Markus chamber reveals the smallest overall perturbation correction and also the smallest energy dependence.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Monte Carlo calculations of beam quality correction factors

Current dosimetry protocols (AAPM, IAEA, DIN) recommend the use of parallel-plate ionization chambers for the measurement of absorbed dose-towater in clinical electron beams. For well-guarded plane-parallel chambers, it is assumed that the perturbation correction pQ is unity for all electron energies. In this study, we present detailed Monte Carlo simulations with the EGSnrc code for the widely...

متن کامل

Monte Carlo calculations of beam quality correction factors kQ for electron dosimetry with a parallel-plate Roos chamber.

Current dosimetry protocols (AAPM, IAEA, DIN) recommend the use of parallel-plate ionization chambers for the measurement of absorbed dose-to-water in clinical electron beams. For well-guarded plane-parallel chambers, it is assumed that the perturbation correction pQ is unity for all electron energies. In this study, we present detailed Monte Carlo simulations with the EGSnrc code for the widel...

متن کامل

Effective Point of Measurement in Cylindrical Ion Chamber for Megavoltage Photon Beams

Introduction For dose measurement in Megavoltage (MV) photon beams with ion chambers, the effect of volume occupied by the air cavity is not negligible. Therefore, the result of measurement should be corrected with a displacement perturbation correction factor (Pdis) or using an effective point of measurement (EPOM). The aim of this study is to calculate the EPOM for cylindrical ion chamber and...

متن کامل

Investigation of surface and buildup region doses for 6 MV high energy photon beams in the presence of a thermoplastic mask

Background: The accuracy and the reproducibility of radiotherapy can be provided by using immobilization devices such as thermoplastic masks. In head and neck cancer radiotherapy, the patients are mostly immobilized by using thermoplastic masks. In this study, the effect of the thermoplastic mask to the surface and buildup region doses was investigated by using Markus parallel plate ion chamber...

متن کامل

On the wall perturbation correction for a parallel-plate NACP-02 chamber in clinical electron beams.

PURPOSE In recent years, several Monte Carlo studies have been published concerning the perturbation corrections of a parallel-plate chamber in clinical electron beams. In these studies, a strong depth dependence of the relevant correction factors (p(wall) and P(cav)) for depth beyond the reference depth is recognized and it has been shown that the variation with depth is sensitive to the choic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017