Cerebral CT perfusion using an interventional C-arm imaging system: cerebral blood flow measurements.

نویسندگان

  • A Ganguly
  • A Fieselmann
  • M Marks
  • J Rosenberg
  • J Boese
  • Y Deuerling-Zheng
  • M Straka
  • G Zaharchuk
  • R Bammer
  • R Fahrig
چکیده

BACKGROUND AND PURPOSE CTP imaging in the interventional suite could reduce delays to the start of image-guided interventions and help determine the treatment progress and end point. However, C-arms rotate slower than clinical CT scanners, making CTP challenging. We developed a cerebral CTP protocol for C-arm CBCT and evaluated it in an animal study. MATERIALS AND METHODS Five anesthetized swine were imaged by using C-arm CBCT and conventional CT. The C-arm rotates in 4.3 seconds plus a 1.25-second turnaround, compared with 0.5 seconds for clinical CT. Each C-arm scan had 6 continuous bidirectional sweeps. Multiple scans each with a different delay to the start of an aortic arch iodinated contrast injection and a novel image reconstruction algorithm were used to increase temporal resolution. Three different scan sets (consisting of 6, 3, or 2 scans) and 3 injection protocols (3-mL/s 100%, 3-mL/s 67%, and 6-mL/s 50% contrast concentration) were studied. CBF maps for each scan set and injection were generated. The concordance and Pearson correlation coefficients (ρ and r) were calculated to determine the injection providing the best match between the following: the left and right hemispheres, and CT and C-arm CBCT. RESULTS The highest ρ and r values (both 0.92) for the left and right hemispheres were obtained by using the 6-mL 50% iodinated contrast concentration injection. The same injection gave the best match for CT and C-arm CBCT for the 6-scan set (ρ = 0.77, r = 0.89). Some of the 3-scan and 2-scan protocols provided matches similar to those in CT. CONCLUSIONS This study demonstrated that C-arm CBCT can produce CBF maps that correlate well with those from CTP.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Using a C-arm CT for Interventional Perfusion Imaging: A Phantom Study to Measure Linearity Between Iodine Concentration and Hounsfield Values

In this work we present phantom measurements to determine the relationship between iodine concentration and measured Hounsfield unit (HU) value using a clinical C-arm CT. These measurements support our current work to use a C-arm CT for brain perfusion imaging in the interventional suite which could e.g. optimize the workflow during stroke therapy. For perfusion imaging a linear relationship be...

متن کامل

C-arm CT measurement of cerebral blood volume and cerebral blood flow using a novel high-speed acquisition and a single intravenous contrast injection.

BACKGROUND AND PURPOSE Assessment of perfusion parameters is important in the selection of patients who are most likely to benefit from revascularization after an acute ischemic stroke. The aim of this study was to evaluate the feasibility of measuring cerebral perfusion parameters with the use of a novel high-speed C-arm CT acquisition in conjunction with a single intravenous injection of cont...

متن کامل

Dynamic contrast-enhanced susceptibility-weighted perfusion imaging of intracranial tumors: a study using a 3T MR scanner.

PURPOSE To determine whether there are statistically significant differences in cerebral blood volume (CBV) and cerebral blood flow (CBF) of brain tumors of different histopathologic types including primary and secondary benign and malignant lesions. To determine whether these measurements relate to tumor grade. MATERIALS AND METHODS Forty-five patients with brain tumors, age 2 to 79 years, u...

متن کامل

C-arm CT measurement of cerebral blood volume: an experimental study in canines.

BACKGROUND AND PURPOSE Cerebral blood volume (CBV) is an important parameter in estimating the viability of brain tissue following an ischemic event. We tested the hypothesis that C-arm CT measurements of CBV would correlate well with those made with perfusion CT (PCT). MATERIALS AND METHODS CBV was measured in 12 canines by using PCT and C-arm CT. Two measurements with each technique were ma...

متن کامل

Quantitative liver tumor blood volume measurements by a C-arm CT post-processing software before and after hepatic arterial embolization therapy: comparison with MDCT perfusion.

PURPOSE We aimed to determine whether the C-arm computed tomography (CT) blood volume (BV) imaging of hepatic tumors performed with a new prototype software is capable of measuring the BV changes in response to hepatic arterial treatments and to validate these quantitative measurements with commercially available multidetector computed tomography (MDCT) perfusion software. METHODS A total of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 32 8  شماره 

صفحات  -

تاریخ انتشار 2011