Energetics and passive dynamics of the ankle in downhill walking.
نویسندگان
چکیده
This study investigated the energetics of the human ankle during the stance phase of downhill walking with the goal of modeling ankle behavior with a passive spring and damper mechanism. Kinematic and kinetic data were collected on eight male participants while walking down a ramp with inclination varying from 0° to 8°. The ankle joint moment in the sagittal plane was calculated using inverse dynamics. Mechanical energy injected or dissipated at the ankle joint was computed by integrating the power across the duration of the stance phase. The net mechanical energy of the ankle was approximately zero for level walking and monotonically decreased (i.e., became increasingly negative) during downhill walking as the slope decreased. The indication is that the behavior of the ankle is energetically passive during downhill walking, playing a key role in dissipating energy from one step to the next. A passive mechanical model consisting of a pin joint coupled with a revolute spring and damper was fit to the ankle torque and its parameters were estimated for each downhill slope using linear regression. The passive model demonstrated good agreement with actual ankle dynamics as indicated by low root-mean-square error values. These results indicate the stance phase behavior of the human ankle during downhill walking may be effectively duplicated by a passive mechanism with appropriately selected spring and damping characteristics.
منابع مشابه
Individual Leg and Joint Work during Sloped Walking for People with a Transtibial Amputation Using Passive and Powered Prostheses
People with a transtibial amputation using passive-elastic prostheses exhibit reduced prosthetic ankle power and push-off work compared to non-amputees and compensate by increasing their affected leg (AL) hip joint work and unaffected leg (UL) ankle, knee, and hip joint and leg work during level-ground walking. Use of a powered ankle–foot prosthesis normalizes step-to-step transition work durin...
متن کاملStabilization and Walking Control for a Simple Passive Walker Using Computed Torque Method (RESEARCH NOTE)
Abstract The simple passive dynamic walker can walk down a shallow downhill slope with no external control or energy input. Nevertheless, the period-one gait stability is only possible over a very narrow range of slopes. Since the passive gaits are extremely sensitive to slope angles, it is important to use a control strategy in order to achieve a wide range of stable walking. The computed to...
متن کاملOptimization of Ankle-Foot Prosthesis with Active Alignment by Passive Elements
Today, often ankle’s active prosthesis is used for transtibial amputated people’s walking, because these prostheses have some advantages such as increasing power and decreasing metabolism. In most of active prosthesis in order to create a movement or increase the force at the push-off, electrical actuators are used like a motor. In cases where a higher-power motor is necessary, the capacity, we...
متن کاملPassive prosthetic ankle-foot mechanism for automatic adaptation to sloped surfaces.
This article describes the development of a prototype prosthetic ankle-foot system that passively adapts to surface slopes on each step of walking. Engineering analyses were performed to design the cam clutch and clutch engagement and disengagement mechanism. The prototype was tested by a veteran with a unilateral transtibial amputation. Kinematic and kinetic data were recorded while the subjec...
متن کاملVirtual slope control of a forward dynamic bipedal walker.
Active joint torques are the primary source of power and control in dynamic walking motion. However the amplitude, rate, timing and phasic behavior of the joint torques necessary to achieve a natural and stable performance are difficult to establish. The goal of this study was to demonstrate the feasibility and stable behavior of an actively controlled bipedal walking simulation wherein the nat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of applied biomechanics
دوره 26 4 شماره
صفحات -
تاریخ انتشار 2010