Extravasation from rupturing aneurysm demonstrated by 3D digital subtraction angiography.
نویسندگان
چکیده
We describe the 3D digital subtraction angiography (3D-DSA) image of extravasation from a rupturing aneurysm. This image clearly showed that the extravasation was coming from a pseudoaneurysm on an aneurysmal wall. To the best of our knowledge, this is the first demonstration of a 3D-DSA image of a rupturing aneurysm.
منابع مشابه
Low wall shear stress is associated with the rupture of intracranial aneurysm with known rupture point: case report and literature review
BACKGROUND Few previous hemodynamic studies demonstrated the detailed features of rupture point of intracranial aneurysms. The hemodynamic simulation for the case that ruptured during angiography was even rare. In the present study, we studied the hemodynamic characteristics of a posterior communicating artery segment aneurysm that ruptured during angiography and detailed the hemodynamic featur...
متن کاملImproved Visualization of Intracranial Vessels with Intraoperative Coregistration of Rotational Digital Subtraction Angiography and Intraoperative 3D Ultrasound
INTRODUCTION Ultrasound can visualize and update the vessel status in real time during cerebral vascular surgery. We studied the depiction of parent vessels and aneurysms with a high-resolution 3D intraoperative ultrasound imaging system during aneurysm clipping using rotational digital subtraction angiography as a reference. METHODS We analyzed 3D intraoperative ultrasound in 39 patients wit...
متن کاملActive rebleeding from a ruptured middle cerebral artery aneurysm during diagnostic catheter angiography.
Rebleeding of cerebral aneurysms was reported during diagnostic angiography previously. However, capturing the exact moment of active rebleeding of a cerebral aneurysm during angiography is extremely rare. Here, a case of a rebleeding middle cerebral artery aneurysm during diagnostic digital subtraction angiography was illustrated, accompanied with a video demonstration of the incident which is...
متن کامل3D rotational digital subtraction angiography may underestimate intracranial aneurysms: findings from two basilar aneurysms.
3D digital subtraction angiography (DSA) allows clinicians to review intracranial aneurysms and other vascular lesions. We report 2 basilar aneurysms that were imaged by both 3D DSA and DynaCT. These 2 techniques produced very different aneurysm appearances. Anterior portions of the aneurysms were invisible on 3D DSA but were revealed by DynaCT. These aneurysms appeared to have been flattened b...
متن کاملContrast Extravasation on Computed Tomography Angiography Imitating a Basilar Artery Trunk Aneurysm in Subsequent Conventional Angiogram-Negative Subarachnoid Hemorrhage: Report of Two Cases with Different Clinical Courses
Contrast extravasation on computed tomography angiography (CTA) is rare but becoming more common, with increasing use of CTA for various cerebral vascular diseases. We report on two cases of spontaneous subarachnoid hemorrhage (SAH) in which the CTA showed a saccular lesion of the upper basilar trunk suggesting a ruptured aneurysm. However, no vascular lesion was observed on immediate subsequen...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 26 6 شماره
صفحات -
تاریخ انتشار 2005