Experiments on Slug Mixing under Natural Circulation Conditions at the Rocom Test Facility Using High Resolution Measurement Technique and Numerical Modeling
نویسندگان
چکیده
ROCOM is a four-loop test facility for the investigation of coolant mixing in the primary circuit of pressurized water reactors. Recently, a new sensor was developed for an improved visualisation and quantification of the coolant mixing in the downcomer. This new sensor spans a dense measuring grid and covers nearly the whole downcomer. In the presented work, special emphasis was given to the comparison of the data of this sensor with the results of calculations using the CFD code ANSYS CFX. A coolant mixing experiment during natural circulation conditions has been conducted. The underlying scenario of this experiment is based on a boron dilution scenario following a SBLOCA event. The corresponding CFD code solution has been obtained using the Best Practice Guidelines. All main effects observed in the measurement are described by the calculation. The detailed comparison reveals that the calculation underestimates the coolant mixing inside the reactor pressure vessel. The measurement data, boundary conditions of the experiment and facility geometry can be made available to other CFD code users for benchmarking.
منابع مشابه
Experiments at the Mixing Test Facility Rocom for Benchmarking of Cfd-codes
For the validation of Computational Fluid Dynamics (CFD) codes experimental data on fluid flow parameters with high resolution in time and space are needed. ROCOM (Rossendorf Coolant Mixing Model) is a test facility for the investigation of coolant mixing in the primary circuit of pressurized water reactors. This facility describes the primary circuit of a German KONVOI type reactor. All import...
متن کاملCoolant Mixing Studies of Natural Circulation Flows at the Rocom Test Facility Using Ansys Cfx
Partial depletion of the primary circuit during a postulated small break loss of coolant accident can lead to the interruption of one-phase flow natural circulation. In this case, the decay heat is removed from the core in the reflux-condenser mode. In case of the partial non-availability of the safety injection system, weakly borated condensate can accumulate in particular in the pump loop sea...
متن کاملExperimental and Numerical Modeling of the Effect of Groundwater Table Lowering on Bearing Capacity of Shallow Square Footings
The lowering of the groundwater table causes the area above the water table to become unsaturated and capillary phenomena to appear in this zone. This means that the bearing capacity of shallow footings will be influenced by capillary stress or matric suction. In this research, the effect of groundwater table lowering on the bearing capacity of a shallow square model footing on dense sand has b...
متن کاملDesign and Implementation of a Reactor Physics Laboratory Simulation Software
The basic structure of a reactor physics laboratory environment simulation software, developed using object modeling technique (OMT), and based on the reactor point kinetic equation, is presented. Also, various capabilities of the simulator in teaching the fundamental concepts of reactor physics are discussed. 
 In this virtual laboratory, student can perform seven different experiments...
متن کاملDesign and Implementation of a Reactor Physics Laboratory Simulation Software
The basic structure of a reactor physics laboratory environment simulation software, developed using object modeling technique (OMT), and based on the reactor point kinetic equation, is presented. Also, various capabilities of the simulator in teaching the fundamental concepts of reactor physics are discussed. In this virtual laboratory, student can perform seven different experiments, ...
متن کامل