Confined chemiluminescence detection of nanomolar levels of H2O2 in a paper-plastic disposable microfluidic device using a smartphone.
نویسندگان
چکیده
We report the design and characterization of a disposable light shielded paper-plastic microfluidic device that can detect nanomolar levels of H2O2 using a smartphone camera and a light sealed accessory. Chemiluminescence reaction of H2O2 with bis(2,4,6-trichlorophenyl)oxalate in the presence of rubrene and imidazole is confined to a paper reaction site where the individual reagents are delivered via plastic microfluidic channels. The net photon emission from the chemiluminescence reactions, detected by using a smartphone, is correlated with H2O2 concentrations. With a total reagent volume of 25 μL, the sensor system was able to detect H2O2 concentrations as low as 250 nM. The smartphone based chemiluminescence sensing system has great potential as a point of care diagnostic tool for monitoring nanomolar levels of H2O2 in biological samples.
منابع مشابه
Smartphone Based Paper-plastic Microfluidic Chemiluminescence Sensor System for H202 Detection
We report a disposable chemiluminescence sensor system for detection and quantification of micromolar levels of hydrogen peroxide (H202) using a hybrid paper/plastic disposable device incorporated to a smart phone (iPhone). A confined photon generation is achieved using a hybrid microfluidic device that consists of a) paper reaction pad and b) plastic microfluidic channels. The reagents are del...
متن کاملComparison between Amperometric and Chemiluminescence methods in detection and dosimetry of cobalt-60 gamma ray emission
Background: Hydrogen peroxide (H2O2), produced by gamma ray irradiation to watery solution, was used as an analytical parameter for dosimetry of cobalt-60 (60Co) radiation. Materials and Methods: Detection of the produced H2O2 was carried out using two methods: an amperometric biosensor fabricated by immobilization of anthraquinone 2-carboxylic acid modified horseradish peroxidase on glassy car...
متن کاملChemiluminescence Determination of Atropine using Luminol-Hemin-H2O2 System
A sensitive and fast chemiluminescence (CL) method has been described for the direct determination of atropine. The method is based on the quenching effect of atropine on the CL signals of the luminol– H2O2 reaction catalyzed by hemin in an alkaline medium. Hemin could strongly enhance the chemiluminescence of the luminol–H2O2 system. The luminophor of the luminol–H2O2–hemin CL system was ident...
متن کاملMicrofluidic device using chemiluminescence and a DNA-arrayed thin film transistor photosensor for single nucleotide polymorphism genotyping of PCR amplicons from whole blood.
This work describes a novel microfluidic device using a thin film transistor (TFT) photosensor integrating a microfluidic channel, a DNA chip platform, and a photodetector for the discrimination of single nucleotide polymorphisms (SNPs). A DNA-arrayed TFT photosensor was used as a DNA chip platform and photo detecting device. Chemiluminescence was used for DNA sensing because chemiluminescence ...
متن کاملFabrication of Laminated Paper-based Analytical Devices (lpad) for Cotinine Detection
The majority of paper-based microfluidic devices were produced by patterning hydrophobic zones via photoresist or wax. Others were created by cutting paper using a laser. We present a fabrication method by craft-cutting and lamination, in a way similar to making an identification card. The method employs a digital craft cutter and roll laminator to produce laminated paper-based analytical devic...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Analyst
دوره 140 15 شماره
صفحات -
تاریخ انتشار 2015