Usefulness of Pulse Oximeter That Can Measure SpO2 to One Digit After Decimal Point.
نویسندگان
چکیده
Pulse oximeters are used to noninvasively measure oxygen saturation in arterial blood (SaO2). Although arterial oxygen saturation measured by pulse oximeter (SpO2) is usually indicated in 1% increments, the value of SaO2 from arterial blood gas analysis is not an integer. We have developed a new pulse oximeter that can measure SpO2 to one digit after the decimal point. The values of SpO2 from the newly developed pulse oximeter are highly correlated with the values of SaO2 from arterial blood gas analysis (SpO2 = 0.899 × SaO2 + 9.944, r = 0.887, P < 0.0001). This device may help improve the evaluation of pathological conditions in patients.
منابع مشابه
Effect of Nail Polish on Pulse Oximetry Findings in Healthy Volunteers: A Randomized Clinical Trail
Background and Objectives: Pulse oximetry is the most common technique for monitoring hemoglobin oxygen saturation (SpO2). Different colors and brands of nail polish may cause disturbance in the reading and interpretation of oxygen saturation. The aim of this study was to determine the effect of different colors of nail polish on oxygen saturation measured by pulse oximeter. Methods: Thirty he...
متن کاملEffect of Digital Block on Pulse Oximeter Signal Detection during General Anesthesia
Pulse oximetry is dependent upon the presence of a pulsating vascular bed. Low pulsatile blood flow in the digits is caused by various factors. Regardless of the cause, if there is sufficient arterial pulse pressure, blocking the sympathetic nerve should cause a local increase in capillary flow and pulse volume. This study was performed to evaluate the effect of digital nerve block on pulse oxi...
متن کاملThe effects of motion on the performance of pulse oximeters in volunteers (revised publication).
BACKGROUND Pulse oximetry is considered a standard of care in both the operating room and the postanesthetic care unit, and it is widely used in all critical care settings. Pulse oximeters may fail to provide valid SpO2 data in various situations that produce low signal-to-noise ratio. Motion artifact is a common cause of oximeter failure and loss of accuracy. This study compares the accuracy a...
متن کاملDesign of Pulse Oximeter Simulator Calibration Equipment
Saturation of peripheral oxygen (SpO2) is one of the most important parameters of vital signs. Pulse oximeter which based on near-infrared spectroscopy is commonly used as a non-invasive method to measure SpO2[1] ,Currently, medical device manufacturers as well as metrology measurement agencies in China usually use pulse oximeter simulator as the commonly accepted functional calibration equipme...
متن کاملNovel Wearable and Wireless Ring-Type Pulse Oximeter with Multi-Detectors
The pulse oximeter is a popular instrument to monitor the arterial oxygen saturation (SPO2). Although a fingertip-type pulse oximeter is the mainstream one on the market at present, it is still inconvenient for long-term monitoring, in particular, with respect to motion. Therefore, the development of a wearable pulse oximeter, such as a finger base-type pulse oximeter, can effectively solve the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Yonago acta medica
دوره 60 2 شماره
صفحات -
تاریخ انتشار 2017