Percutaneous closure of Blalock-Taussig shunts using Gianturco coils.
نویسندگان
چکیده
Permeability of a Blalock-Taussig shunt can increase the risk of endocarditis and ventricular overload. Percutaneous embolization of these shunts gives variable results. We report our experience in 10 patients with percutaneous closure of modified Blalock-Taussig shunts using retrograde arterial embolization with Gianturco coils. The patients' median age was 2.8 years, and their median weight was 12 kg. Most patients had minor stenosis of the distal portion of the anastomosis. In all cases, complete closure of the shunt was achieved without complications using a median of one coil per patient. The technique was feasible, safe, effective, and inexpensive.
منابع مشابه
Percutaneous closure of a modified Blalock-Taussig shunt using an amplatzer vascular plug.
Modified Blalock-Taussig shunts are usually clamped during the successive corrective or palliative surgical procedures carried out to treat underlying congenital heart disease, though at times they may be left permeable for a number of reasons. Subsequently, when this is no longer considered necessary and closure is indicated, the method of choice is percutaneous embolization using various coil...
متن کاملClosure of Blalock-Taussig shunts using a new detachable coil device.
Two children underwent interventional closure of a modified Blalock-Taussig shunt using a new detachable coil system (Duct-Occlud). This procedure has advantages over currently available materials to occlude these and other communications between the systemic and pulmonary circulations.
متن کاملTranscatheter closure of Blalock-Taussig shunts with a modified Rashkind umbrella delivery system.
Transcatheter occlusion of Blalock-Taussig shunts was successfully performed in three children with the Rashkind double umbrella occluding device. Complete occlusion was confirmed angiographically in two patients and echocardiographically in the third. The delivery system was adapted for use through smaller sheaths making it more suitable for small children or arterial access.
متن کاملPerigraft seroma complicating the modified Blalock-Taussig shunts: two consecutive instances with review of literature.
Systemic-to-pulmonary artery shunts using polytetrafluoroethylene (PTFE) (modified Blalock-Taussig shunt) are being used successfully in palliation of cyanotic congenital heart diseases. Graft thrombosis is by far the most common complication of the procedure. Persistant serum leakage through PTFE graft causing perigraft seroma is a rare but devastating complication resulting in increased durat...
متن کاملTranscatheter closure of Blalock-Taussig anastomosis with brachial access in a child with obstruction of the left subclavian artery and secondary subclavian steal syndrome
In case of significant hypoxia in the course of congenital heart defect, when definite surgery is difficult, various palliative procedures are performed. One of the most frequently used is a modified Blalock-Taussig (BT) anastomosis. The BT anastomosis is closed during cardiac surgery. In some patients, BT anastomosis remains open after the surgery and requires closure by cardiac intervention u...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Revista espanola de cardiologia
دوره 61 12 شماره
صفحات -
تاریخ انتشار 2008