Cross-imaging platform comparison of ultrasonic backscatter coefficient measurements of live rat tumors.

نویسندگان

  • Lauren A Wirtzfeld
  • Goutam Ghoshal
  • Zachary T Hafez
  • Kibo Nam
  • Yassin Labyed
  • Janelle J Anderson
  • Maria-Teresa Herd
  • Alexander Haak
  • Zhi He
  • Rita J Miller
  • Sandhya Sarwate
  • Douglas G Simpson
  • James A Zagzebski
  • Timothy A Bigelow
  • Michael L Oelze
  • Timothy J Hall
  • William D O'Brien
چکیده

OBJECTIVE To translate quantitative ultrasound (QUS) from the laboratory into the clinic, it is necessary to demonstrate that the measurements are platform independent. Because the backscatter coefficient (BSC) is the fundamental estimate from which additional QUS estimates are calculated, agreement between BSC results using different systems must be demonstrated. This study was an intercomparison of BSCs from in vivo spontaneous rat mammary tumors acquired by different groups using 3 clinical array systems and a single-element laboratory scanner system. METHODS Radio frequency data spanning the 1- to 14-MHz frequency range were acquired in 3 dimensions from all animals using each system. Each group processed their radio frequency data independently, and the resulting BSCs were compared. The rat tumors were diagnosed as either carcinoma or fibroadenoma. RESULTS Carcinoma BSC results exhibited small variations between the multiple slices acquired with each transducer, with similar slopes of BSC versus frequency for all systems. Somewhat larger variations were observed in fibroadenomas, although BSC variations between slices of the same tumor were of comparable magnitude to variations between transducers and systems. The root mean squared (RMS) errors between different transducers and imaging platforms were highly variable. The lowest RMS errors were observed for the fibroadenomas between 4 and 5 MHz, with an average RMS error of 4 x 10(-5) cm(-1)Sr(-1) and an average BSC value of 7.1 x 10(-4) cm(-1)Sr(-1), or approximately 5% error. The highest errors were observed for the carcinoma between 7 and 8 MHz, with an RMS error of 1.1 x 10(-1) cm(-1)Sr(-1) and an average BSC value of 3.5 x 10(-2) cm(-1)Sr(-1), or approximately 300% error. CONCLUSIONS This technical advance shows the potential for QUS technology to function with different imaging platforms.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Backscatter coefficient measurements using a reference phantom to extract depth-dependent instrumentation factors.

In previous work, we demonstrated that accurate backscatter coefficient measurements are obtained with a data reduction method that explicitly accounts for experimental factors involved in recording echo data. An alternative, relative processing method for determining the backscatter coefficient and the attenuation coefficient is presented here. This method involves comparison of echo data from...

متن کامل

Interlaboratory comparison of ultrasonic backscatter coefficient measurements from 2 to 9 MHz.

OBJECTIVE As are the attenuation coefficient and sound speed, the backscatter coefficient is a fundamental ultrasonic property that has been used to characterize many tissues. Unfortunately, there is currently far less standardization for the ultrasonic backscatter measurement than for the other two, as evidenced by a previous American Institute of Ultrasound in Medicine (AIUM)-sponsored interl...

متن کامل

High Frequency Backscatter Measurements of Bovine Tissues with Unfocused and Focused Transducers

In order to improve resolution of ultrasonic imaging, high frequency scanners which are employed in the range 20 MHZ to 50 MHz are needed. As a result, it is critical to obtain data on ultrasonic scattering and attenuation in this frequency range. At these high frequencies, it is not feasible to make scattering measurements with unfocused transducers; therefore focused transducers are needed. U...

متن کامل

Cross-imaging system comparison of backscatter coefficient estimates from a tissue-mimicking material.

A key step toward implementing quantitative ultrasound techniques in a clinical setting is demonstrating that parameters such as the ultrasonic backscatter coefficient (BSC) can be accurately estimated independent of the clinical imaging system used. In previous studies, agreement in BSC estimates for well characterized phantoms was demonstrated across different laboratory systems. The goal of ...

متن کامل

Comparison of ultrasound attenuation and backscatter estimates in layered tissue-mimicking phantoms among three clinical scanners.

Backscatter and attenuation coefficient estimates are needed in many quantitative ultrasound strategies. In clinical applications, these parameters may not be easily obtained because of variations in scattering by tissues overlying a region of interest (ROI). The goal of this study is to assess the accuracy of backscatter and attenuation estimates for regions distal to nonuniform layers of tiss...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine

دوره 29 7  شماره 

صفحات  -

تاریخ انتشار 2010