Revised delta34S reference values for IAEA sulfur isotope reference materials S-2 and S-3.

نویسندگان

  • Jacqueline L Mann
  • Robert D Vocke
  • W Robert Kelly
چکیده

Revised delta(34)S reference values with associated expanded uncertainties (95% confidence interval (C.I.)) are presented for the sulfur isotope reference materials IAEA-S-2 (22.62 +/- 0.16 per thousand) and IAEA-S-3 (-32.49 +/- 0.16 per thousand). These revised values are determined using two relative-difference measurement techniques, gas source isotope ratio mass spectrometry (GIRMS) and double-spike multi-collector thermal ionization mass spectrometry (MC-TIMS). Gas analyses have traditionally been considered the most robust for relative isotopic difference measurements of sulfur. The double-spike MC-TIMS technique provides an independent method for value-assignment validation and produces revised values that are both unbiased and more precise than previous value assignments. Unbiased delta(34)S values are required to anchor the positive and negative end members of the sulfur delta (delta) scale because they are the basis for reporting both delta(34)S values and the derived mass-independent Delta(33)S and Delta(36)S values.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of sulfate sources in high-elevation Asian precipitation using stable sulfur isotopes.

Stable sulfur isotope measurements (delta34S) made on samples collected from a 2 m snowpit on the Inilchek Glacier, Tien Shan Mountains (42.16 degrees N, 80.25 degrees E, 5100 m) are used to estimate sources of sulfate (SO4(2-)) in high-elevation Central Asian precipitation. Comparison of snowpit oxygen isotope (delta18O) data with previous work constrains the age of the snowpit samples to the ...

متن کامل

On-line Quantitative Determination of 2H/1H Isotope Ratios in Organic and Water Samples Using an Elemental Analyser Coupled to an Isotope Ratio Mass Spectrometer

A rapid continuous-Ñow technique for the quantitative determination of hydrogen isotope ratios in organic materials and water, at natural abundance levels, is described. Samples are pyrolysed in a helium stream at 1080 ÄC over an inert form of carbon. Hydrogen is separated from the other pyrolysis gases by gas chromatography and enters the ion source of the isotope ratio mass spectrometer (IRMS...

متن کامل

Nicotine, acetanilide and urea multi-level 2H-, 13C- and 15N-abundance reference materials for continuous-flow isotope ratio mass spectrometry.

Accurate determinations of stable isotope ratios require a calibration using at least two reference materials with different isotopic compositions to anchor the isotopic scale and compensate for differences in machine slope. Ideally, the delta values of these reference materials should bracket the isotopic range of samples with unknown delta values. While the practice of analyzing two isotopica...

متن کامل

Stable sulfur isotope fractionation by the green bacterium Chlorobaculum parvum during photolithoautotrophic growth on sulfide.

Growing cultures of the green obligate photolithotroph, Chlorobaculum parvum DSM 263T (formerly Chlorobium vibrioforme forma specialis thiosulfatophilum NCIB 8327), oxidized sulfide quantitatively to elemental sulfur, with no sulfate formation. In the early stages of growth and sulfide oxidation, the sulfur product became significantly enriched with 34S, with a maximum delta34S above +5 per tho...

متن کامل

Organic Reference Materials for Hydrogen, Carbon, and Nitrogen Stable Isotope-Ratio Measurements: Caffeines, n-Alkanes, Fatty Acid Methyl Esters, Glycines, L-Valines, Polyethylenes, and Oils.

An international project developed, quality-tested, and determined isotope-δ values of 19 new organic reference materials (RMs) for hydrogen, carbon, and nitrogen stable isotope-ratio measurements, in addition to analyzing pre-existing RMs NBS 22 (oil), IAEA-CH-7 (polyethylene foil), and IAEA-600 (caffeine). These new RMs enable users to normalize measurements of samples to isotope-δ scales. Th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Rapid communications in mass spectrometry : RCM

دوره 23 8  شماره 

صفحات  -

تاریخ انتشار 2009