Agreement between hearing thresholds measured in non-soundproof work environments and a soundproof booth.

نویسندگان

  • T W Wong
  • T S Yu
  • W Q Chen
  • Y L Chiu
  • C N Wong
  • A H S Wong
چکیده

AIMS To study the agreement between audiometric test results measured in non-soundproof environments at the worksite, and in a soundproof booth. METHODS In a cross sectional prevalence study on noise induced hearing loss, 885 transport workers whose hearing thresholds were measured by a standard audiometric test method in non-soundproof environments at the worksite were identified to have some hearing loss (>25 dB), and were retested in a soundproof booth. RESULTS At 4-8 KHz, the mean of the absolute differences in hearing threshold obtained by these two methods was 2 dB or less. When the proportions of hearing loss (> or =30 dB for any frequencies at 3-8 KHz, or > or =90 dB for three low frequencies at 0.5-2 KHz, or > or =90 dB for three high frequencies at 3-6 KHz) were compared, considerable differences existed. A much better agreement was obtained when the criteria for hearing loss as measured in the field test under non-soundproof conditions were relaxed by 5 dB. At 4 KHz, the difference between the proportion of subjects with hearing loss as measured in the field and that as measured in the booth was the smallest. The kappa statistic was highest at 3 and 4 KHz. CONCLUSIONS Audiometric test results conducted in non-soundproof environments in the field are comparable to those obtained in a soundproof environment among transport workers with a hearing loss of >25 dB. The hearing threshold at 4 KHz appears suitable for the estimation of the prevalence of hearing loss when appropriate adjustments are made in the diagnostic criteria.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Accuracy of IOS Device-based uHear as a Screening Tool for Hearing Loss: A Preliminary Study From the Middle East.

OBJECTIVES To determine and explore the potential use of uHear as a screening test for determining hearing disability by evaluating its accuracy in a clinical setting and a soundproof booth when compared to the gold standard conventional audiometry.  . METHODS Seventy Sultan Qaboos University students above the age of 17 years who had normal hearing were recruited for the study. They underwen...

متن کامل

Speech recognition thresholds in noisy areas : Reference values for normal hearing adults Summary

In audiology clinics, complaints about difficulties in speech recognition in noise environments are frequent, even for normal-hearing individuals. Thus, the audiologist must not only identify a hearing loss, but also analyze speech recognition, under noisy conditions similar to those found in our daily lives. Aim: Determine the reference value for the recognition of phrases under noisy conditio...

متن کامل

Hearing threshold evaluation of dentistsin Babol (North of Iran)

Introduction:Noise in dental offices is one of the risk factors in the workplace. One of the major effects of noise is hearing loss. This study aimed to determine the effects of noise on hearing thresholds of dentists of Babol city. Methods:This descriptive analytical cross-sectional study was performed on 40 dentists in Babol City (as case group) and 40 office workers (as control group). He...

متن کامل

Evaluation method for hearing aid fitting under reverberation: comparison between monaural and binaural hearing aids.

Some hearing-impaired persons with hearing aids complain of listening difficulty under reverberation. No method, however, is currently available for hearing aid fitting that permits evaluation of hearing difficulty caused by reverberations. In this study, we produced speech materials with a reverberation time of 2.02 s that mimicked a reverberant environment (a classroom). Speech materials with...

متن کامل

RR840 - Optimum test conditions and variability of otoacoustic emission testing in individuals with normal hearing

This study investigates issues important for the potential usefulness and practical application of OAE testing within an occupational health surveillance programme. Before this technique can be used within health surveillance, it is important to understand how reliable the measurements are and the level of change that could be detected over time within individuals. As any test of hearing functi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Occupational and environmental medicine

دوره 60 9  شماره 

صفحات  -

تاریخ انتشار 2003