Improper Fuse Wire Replacement, and Possible Association with Commercial Fires
نویسندگان
چکیده
The rewireable fuse or cutout is widely used in Bangladesh and elsewhere, in spite of the very real danger of improper replacement of fuse wires. To assess the problem, a preliminary survey of buildings, electrical shops, and electricians were conducted. The majority of buildings and retail establishments were found to use fuse wires. Electricians were found to use copper of arbitrary thicknesses as fuses, and were unaware of the existence of specialized fuse wires. Every year, there are numerous fires in the garments and other industries, causing hundreds of deaths. As the vast majority of these fires are of electrical origin, the evidence is strong that improper fuse wiring may have been the cause of the fires. The number of smaller fires which do not make it to the news is likely to be orders of magnitude greater than the publicized fires. Even when the origin is not electrical, insulation failures may cause secondary electrical fires, that may cause the fire to spread rapidly to the rest of the building, making it hard to extinguish. Index Term-Fuse, wire, cutout, industry, fires.
منابع مشابه
ارزیابی ریسک حریق در ایستگاههای خط 1 مترو شهر تهران)پست یکسوساز( با روش تجزیه و تحلیل درخت خطا
Background and a ims: Subway system including infrastructure systems in the transportation industry can potentially exposed to fire, flood, earthquake and similar events and could create catastrophic losses to society. Therefore, this study aims to assess the risk of fire in Tehran subway stations (line 1). Methods: Inperforming this research, after the identifying the fire hazard resources...
متن کاملChecking and replacing fuses
Although we often think of fuses as a nuisance, they play an important safety role in preventing damage to equipment due to electrical overloading, thereby reducing the risk of electrical shock to patients and staff. You should not dismiss a blown fuse as an inconvenience. It may be a sign that a real fault has developed, giving you the chance to find and fix the problem before any serious dama...
متن کاملCorrelation of Metallic Fuse/tamper Chemical Reaction with Electrical Recovery
Recent experiments have been conducted at NRL which were designed to evaluate the chemical reactivity of exploding conductor fuses and to relate the chemical process to fuse electrical performance. In these experiments, metallic fuses including aluminum wire and foils, lithium-aluminum alloy wire, and copper wire were vaporized in distilled water. Additionally, less precise tests were conducted...
متن کاملP-53: The Unexpected Occurrence of SpontaneousPregnancy during Hormone ReplacementTherapy for Premature Ovarian Failure
Background: Premature ovarian failure (POF) is defined by the association of amenorrhea, hypoestrogenism and elevated (menopausal) levels of serum gonadotropins before age of 40 years-old. This condition affects approximately %1 of women under 40 years of age. Physiologic replacement of ovarian steroid hormones seems rational until the age of normal menopause. Temporary return of ovarian functi...
متن کاملOn-line Red-scale Measurement System for Wire Rod Coil
This article deals with a red-scale measurement system which can be applied to Wire Rod Production Line in POSCO (Pohang Iron and Steel Company). A red-scale is a type of oxidized Fe coated on the surface of wire rod and as the name means it has red color. The main cause of red-scale is an improper control of cooling process after final milling stage. To control the cooling process we need to m...
متن کامل