Accurate determination of CT point‐spread‐function with high precision

نویسندگان

  • Akihiro Kayugawa
  • Masaki Ohkubo
  • Shinichi Wada
چکیده

The measurement of modulation transfer functions (MTFs) in computed tomography (CT) is often performed by scanning a point source phantom such as a thin wire or a microbead. In these methods the region of interest (ROI) is generally placed on the scanned image to crop the point source response. The aim of the present study was to examine the effect of ROI size on MTF measurement, and to optimize the ROI size. Using a 4 multidetector-row CT, MTFs were measured by the wire and bead methods for three types of reconstruction kernels designated as 'smooth', 'standard', and 'edge-enhancement' kernels. The size of a square ROI was changed from 30 to 50 pixels (approximately 2.9 to 4.9 mm). The accuracies of the MTFs were evaluated using the verification method. The MTFs measured by the wire and bead methods were dependent on ROI size, particularly in MTF measurement for the 'edge-enhancement' kernel. MTF accuracy evaluated by the verification method changed with ROI size, and we were able to determine the optimum ROI size for each method (wire/bead) and for each kernel. Using these optimal ROI sizes, the MTF obtained by the wire method was in strong agreement with the MTF obtained by the bead method in each kernel. Our data demonstrate that the difficulties in obtaining accurate MTFs for some kernels such as edge-enhancement can be overcome by incorporating the verification method into the wire and bead methods, allowing optimization of the ROI size to accurately determine the MTF.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

HIGH-PERFORMANCE LIQUID CHROMATOGRAPHIC DETERMINATION OF THEOPHYLLINE IN HUMAN SERUM

A simple, rapid and sensitive HPLC method for the determination of theophylline (T) in human serum has been developed. An isocratic system consisting of a /-l Bondapak C18 column, mobile phase of methanol, phosphate buffer (22:78, pH=4.5), and a flow rate of 1.4 mL/min was used. The eluent was detected by UV at 275 nm at room temperature. 8-Chlorotheophylline (8-CT) was used as an internal ...

متن کامل

High Performance Liquid Chromatography Determination of Sertraline in Human

       An accurate and sensitive reversed-phase high-performance liquid chromatograph-ic method for determination of sertraline in human serum is described using 4-chloro-7-nitrobenzofurazan as pre-column derivatization agent. The drug and an internal standard (azithrimycin) were extracted from serum using a mixture of diethyl ether-chloroform and subjected to the pre-column derivatization with...

متن کامل

Promotion of the Cupellation Method for Accurate Determination of Gold Alloy’s Karat Containing Platinum-Group Metals

The main standard method for gold karat determination is the cupellation method. However, this method is not sufficiently accurate to determine gold karat in the presence of insoluble Platinum–Group Metals (PGMs), such as Ir, Ru, and Rh. In this study, for the first time, a complementary method that can be used coupled with the reference cupellation method is presented for the high...

متن کامل

Design and Fabrication Process of MTF Phantom CT Scan

Introduction: One of the main steps in the optimization process in diagnostic imaging is the quality control of radiology devices. The usual method of CT scan calibration is used of a phantom. The phantom created a certain weakening for the radiation through which it passes. One of the most suitable methods for quantitative analysis of the resolution and contrast in CT scan im...

متن کامل

Stellar Photometry and Astrometry with Discrete Point Spread Functions

The key features of the MATPHOT algorithm for precise and accurate stellar photometry and astrometry using discrete Point Spread Functions are described. A discrete Point Spread Function (PSF) is a sampled version of a continuous PSF which describes the two-dimensional probability distribution of photons from a point source (star) just above the detector. The shape information about the photon ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2013