Field Tests for Evaluating the Aerobic Work Capacity of Firefighters
نویسندگان
چکیده
Working as a firefighter is physically strenuous, and a high level of physical fitness increases a firefighter's ability to cope with the physical stress of their profession. Direct measurements of aerobic capacity, however, are often complicated, time consuming, and expensive. The first aim of the present study was to evaluate the correlations between direct (laboratory) and indirect (field) aerobic capacity tests with common and physically demanding firefighting tasks. The second aim was to give recommendations as to which field tests may be the most useful for evaluating firefighters' aerobic work capacity. A total of 38 subjects (26 men and 12 women) were included. Two aerobic capacity tests, six field tests, and seven firefighting tasks were performed. Lactate threshold and onset of blood lactate accumulation were found to be correlated to the performance of one work task (r(s) = -0.65 and -0.63, p<0.01, respectively). Absolute (mL · min(-1)) and relative (mL · kg(-1) · min(-1)) maximal aerobic capacity was correlated to all but one of the work tasks (r(s) = -0.79 to 0.55 and -0.74 to 0.47, p<0.01, respectively). Aerobic capacity is important for firefighters' work performance, and we have concluded that the time to row 500 m, the time to run 3000 m relative to body weight (s · kg(-1)), and the percent of maximal heart rate achieved during treadmill walking are the most valid field tests for evaluating a firefighter's aerobic work capacity.
منابع مشابه
Laboratory or Field Tests for Evaluating Firefighters' Work Capacity?
Muscle strength is important for firefighters work capacity. Laboratory tests used for measurements of muscle strength, however, are complicated, expensive and time consuming. The aims of the present study were to investigate correlations between physical capacity within commonly occurring and physically demanding firefighting work tasks and both laboratory and field tests in full time (N = 8) ...
متن کاملStudy of Aerobic Capacity and its Relationship with Lifestyle among Iranian Firefighters in an Industrial Complex
Background: Few quantitative studies in our country have been conducted to investigate the status of cardiovascular fitness in firefighters. The objective of this study was evaluation of aerobic capacity and its relation with the lifestyle of firefighters. Methods: This study was conducted in 2014 and 165 male firefighters participated in the study. Information such as demographic data as wel...
متن کاملبررسی حداکثر ظرفیت هوازی (VO2max) و عوامل مرتبط با آن در آتشنشانان
Background and aims: Maximal oxygen uptake (VO2max) represents physical work capacity. Therefore in physically demanding jobs like firefighting, precise evaluation of employees' aerobic capacity is critical in order to ensure their physical capabilities and fitness for work duties. The aim of this study was to evaluate the maximal aerobic capacity and its associated factors in firefighters. ...
متن کاملMultivariate Statistical Assessment of Predictors of Firefighters’ Muscular and Aerobic Work Capacity
Physical capacity has previously been deemed important for firefighters physical work capacity, and aerobic fitness, muscular strength, and muscular endurance are the most frequently investigated parameters of importance. Traditionally, bivariate and multivariate linear regression statistics have been used to study relationships between physical capacities and work capacities among firefighters...
متن کاملبرآورد حداکثر ظرفیت هوازی پرسنل آتشنشان با استفاده از آزمون پله: مطالعه موردی با استفاده از پلهای با قابلیت تنظیم ارتفاع
Introduction: Firefighting is amongst jobs that require high physical strength and high aerobic capacity. These are required because of the nature and the physical demands of the job. The maximum aerobic capacities of firefighters were investigated using the step test. Methods: This cross-sectional descriptive-analytical study was conducted on 73 firefighters. At first, demographic informati...
متن کامل