Evaluation of the vertebrobasilar-posterior system by transcranial color duplex sonography in adults.

نویسندگان

  • M Schöning
  • J Walter
چکیده

BACKGROUND AND PURPOSE The transcranial color duplex sonography technique was applied to the vertebrobasilar-posterior system to provide normal data for clinical application. METHODS The intracranial posterior circulation was studied in 49 healthy volunteers (mean +/- SD age, 35 +/- 12 years) by a transcranial and suboccipital approach with a 2.0-MHz sector transducer of a computed sonography system. RESULTS The posterior cerebral artery and the vertebrobasilar system were depicted clearly in the color Doppler mode. Pulsed Doppler signals could be recorded in the posterior cerebral (100%), basilar (92%), and vertebral arteries (89%). The following normal values were provided for all vessels: systolic peak, end-diastolic maximum, time-averaged, and time-averaged maximum velocities; resistance and pulsatility indexes; and a spectral broadening index. Mean +/- SD values were 45.9 +/- 9.6, 45.5 +/- 10.8, and 39.2 +/- 10.6 cm/sec for time-averaged maximum velocity, and 28.3 +/- 6.5, 30.6 +/- 7.2, and 24.7 +/- 8.4 cm/sec for time-averaged velocity in the posterior cerebral, basilar, and vertebral arteries, respectively. In a reproducibility study, duplex measurements of the posterior cerebral arteries were repeated in 27 subjects. The correlation between the two examiners was high (r = 0.56, p less than or equal to 0.0001 for time-averaged maximum velocity). CONCLUSIONS Color duplex sonography of the vertebrobasilar-posterior system is a new, noninvasive, bedside investigative technique. It permits visualization of artery flow in real time, relating these to adjacent brain and cranial structures, as well as angle-corrected duplex measurement of "true" flow velocities at defined sites of the vessels. Thus, it will open new diagnostic possibilities in disorders of the posterior circulation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Imaging of the intracranial vertebrobasilar system using color-coded ultrasound.

BACKGROUND Anatomic variety and difficult accessibility of the vertebrobasilar arteries pose considerable problems to conventional ultrasound. We evaluated the diagnostic potential of transcranial color-coded sonography in the distal part of this system. METHODS We insonated the intracranial section of the vertebrobasilar arteries through the foramen magnum window in 24 healthy individuals us...

متن کامل

Vertebrobasilar transcranial color-coded duplex ultrasonography: improvement with echo enhancement.

BACKGROUND AND PURPOSE The diagnostic yield of vertebrobasilar transcranial color-coded duplex ultrasonography (US) is often hampered by insufficient acoustic penetration, anatomic variations, and vessel tortousity. The purpose of this study was to evaluate the effect of echo enhancement on vertebrobasilar transcranial color-coded duplex US. METHODS In 23 consecutive patients (mean age, 61.0 ...

متن کامل

Comparison of transcranial power Doppler and contrast-enhanced color-coded sonography in the identification of intracranial arteries.

Power-based transcranial color-coded sonography and contrast-enhanced transcranial color-coded sonography are ultrasonographic techniques that allow improved visualization of vascular structures. The present study was designed to investigate and compare the diagnostic capacity and applicability of both methods in the assessment of intracranial vessels of the circle of Willis (33 patients) and t...

متن کامل

Visualization of the basilar artery by transcranial color-coded duplex sonography : comparison with postmortem results.

BACKGROUND AND PURPOSE Transcranial color-coded sonography (TCCS) via the suboccipital approach allows direct and continuous visualization of the basilar artery (BA). In this study, we intended to evaluate the ability of native TCCS in visualizing the length of the BA by means of a comparison with postmortem measurements. METHODS The BA was prospectively studied by TCCS shortly before death (...

متن کامل

Contrast-enhanced transcranial color-coded real-time sonography. Results of a phase-two study.

BACKGROUND AND PURPOSE Transcranial color-coded real-time sonography has been developed as a promising new bedside procedure to monitor central nervous system parenchymal and vascular pathology; the present study was designed to investigate the potential role of galactose microparticles (SH U 508 A) as a new ultrasound contrast-enhancing agent for transcranial sonography. METHODS Ten patients...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Stroke

دوره 23 9  شماره 

صفحات  -

تاریخ انتشار 1992