Validating the Bland-Altman Method of Agreement
نویسندگان
چکیده
Bland-Altman’s analysis and plot are the most common methods used to assess the relative agreement between two analytical methods that measure the continuous variables measured on the same scale. Many agreement studies have shown that using the t-test or the Pearson’s product-moment correlation is flawed when measuring the agreement or detecting the bias. Bland-Altman proposed graphical techniques for analyzing method comparison and validation studies and many articles advocating their approach or variations of it have since appeared in many journals. The basic concept of Bland-Altman’s approach is the visualization of the difference of the measurements made by the two methods, then plotting the differences (diff) or the bias (Y-axis) versus the mean (mean) of the two readings (X-axis). In addition, additional reference lines such as the zero bias line and 95% upper (0 + 1.96 Sdiff) and 95% lower (0 1.96 Sdiff) are also overlaid on the same scatter plot. When there is no systematic bias, it is easy to verify from the plot if the differences are symmetrical around zero. If there is no relationship between the differences and the averages, the agreement between the two methods may be summarized using the means and standard deviations test methods. Bland-Altman’s plots have become an essential requirement in validity or method-comparison studies and Bland-Altman’s original paper has been cited over more than 11500 occasions—compelling evidence of its importance in medical research. However, some recent reports discussed the flaws of the Bland-Altman’s graphical methods and advocate the use of regression approach especially when the bias distribution shows heterogeneous bias distribution. Therefore, we are proposing a robust enhanced Bland-Altman’s analysis which combines a superior graphical display of bias distribution supplemented with a regression analysis between the diff and the standard measurement. The primary objective of this poster presentation is using advanced SAS statistical and graphical procedures to demonstrate our enhanced features of robust BlandAltman’s analysis and compare its performances with the original Bland-Altman’s method using six diverse types of simulated data sets.
منابع مشابه
Application of Bland-Altman Method in Comparing Transrectal and Transabdominal Ultrasonography for Estimating Prostate Volume
Background: Estimating prostate volume using less invasive transabdominal ultrasonography (TAUS) instead of transrectal ultrasonography (TRUS) is of interest in terms of identifying their agreement level. Previous reports on this subject, applied general correlation coefficient as the level of agreement. This study uses Bland-Altman method to quantify TAUS and TRUS agreement on estimating prost...
متن کاملComparison of Microbiological and High-Performance Liquid Chromatographic Methods for Determination of Clarithromycin Levels in Plasma
An agar well diffusion bioassay method for determination of clarithromycin in human plasma, using Micrococcus Luteus ATCC 9341 as the assay organism, was compared with a selective high-performance liquid chromatographic (HPLC) method with UV detection. Spiked plasma was used to prepare standard and control samples for both methods. The results of the bioassay analyses with spiked plasma samples...
متن کاملComparison of Microbiological and High-Performance Liquid Chromatographic Methods for Determination of Clarithromycin Levels in Plasma
An agar well diffusion bioassay method for determination of clarithromycin in human plasma, using Micrococcus Luteus ATCC 9341 as the assay organism, was compared with a selective high-performance liquid chromatographic (HPLC) method with UV detection. Spiked plasma was used to prepare standard and control samples for both methods. The results of the bioassay analyses with spiked plasma samples...
متن کاملاعتبارسنجی روشهای اندازهگیری طول کانال دندان: یک مطالعه روش شناختی
Background and Aims: Acurate measurements of variables are crucial in epidemiological studies. Therefore, even the best design cannot prevent bugs caused due to the lack of reliability and validity measurement in studies. The aim of this study is to determine the validity of teeth-canal measurement. Materials and Methods: This methodological study used available data of patients referred t...
متن کاملTesting the agreement of medical instruments: overestimation of bias in the Bland-Altman analysis.
OBJECTIVES The Bland-Altman method is the most popular method used to assess the agreement of medical instruments. The main concern about this method is the presence of proportional bias. The slope of the regression line fitted to the Bland-Altman plot should be tested to exclude proportional bias. The aim of this study was to determine whether the overestimation of bias in the Bland-Altman ana...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2009