Sources of Error in UV Radiation Measurements

نویسندگان

  • Thomas C. Larason
  • Christopher L. Cromer
چکیده

Increasing commercial, scientific, and technical applications involving ultraviolet (UV) radiation have led to the demand for improved understanding of the performance of instrumentation used to measure this radiation. There has been an effort by manufacturers of UV measuring devices (meters) to produce simple, optically filtered sensor systems to accomplish the varied measurement needs. We address common sources of measurement errors using these meters. The uncertainty in the calibration of the instrument depends on the response of the UV meter to the spectrum of the sources used and its similarity to the spectrum of the quantity to be measured. In addition, large errors can occur due to out-of-band, non-linear, and non-ideal geometric or spatial response of the UV meters. Finally, in many applications, how well the response of the UV meter approximates the presumed action spectrum needs to be understood for optimal use of the meters.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The use of polyvinyl chloride films dyed with methyl red in radiation dosimetry

Background: The purpose of this work was to investigate the use of polyvinyl chloride (PVC) dyed with methyl red as a high dose radiation dosimetry. Materials and Methods: Commercial PVC films from Sabic made from resins PVC57S with thickness of 60 µm and methyl red with a molecular weight of 269.31 were used. Irradiation was carried out using a 60Co γ-ray generator with sources arr...

متن کامل

Comparative Measurements of Radon Concentration in Soil Using Passive and Active Methods in High Level Natural Radiation Area (HLNRA) of Ramsar

Background: Radon and its daughters are amongst the most important sources of natural exposure in the world. Soil is one of the significant sources of radon/thoron due to both radium and thorium so that the emanated thoron from it may cause increased uncertainties in radon measurements. Recently, a diffusion chamber has been designed and optimized for passive discriminative measurements of rado...

متن کامل

Evaluation of solar ultraviolet radiation in Zanjan city using the ultraviolet index

Background and Objective: Monitoring the amount of ultraviolet radiation from sunlight can provide a basis for assessing people's exposure, raise public awareness and warn people against this radiation. Measuring the sun's ultraviolet index over a working period is an accurate choice to achieve this goal. Materials and Methods: In this study, the amount of solar UV index in one of the outdoor ...

متن کامل

Physical characteristics and sources of exposure to artificial UV radiation

UV radiation belongs to the non-ionizing part of the electromagnetic spectrum and ranges between 100 nm and 400 nm; 100 nm has been chosen arbitrarily as the boundary between nonionizing and ionizing radiation. UV radiation is conventionally categorized into 3 regions: UVA (>315–400 nm), UVB (>280–315 nm) and UVC (>100–280 nm) (Figure 1). These categories have been confirmed by the Commission I...

متن کامل

Application of MCNP4C Monte Carlo code in radiation dosimetry in heterogeneous phantom

Background: In treating patients with radiation, the degree of accuracy for the delivery of tumor dose is recommended to be within ± 5% by ICRU in report 24. The experimental studies have shown that the presence of low-density inhomogeneity in areas such as the lung can lead to a greater than 30% change in the water dose data. Therefore, inhomogeneity corrections should be used in treatment pla...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 106  شماره 

صفحات  -

تاریخ انتشار 2001