A microfluidic device to reduce treatment time of intracytoplasmic sperm injection.

نویسندگان

  • Koji Matsuura
  • Takuya Uozumi
  • Takuya Furuichi
  • Ikuyo Sugimoto
  • Mieko Kodama
  • Hiroaki Funahashi
چکیده

OBJECTIVE To develop a microfluidic device that can reduce the intracytoplasmic sperm injection (ICSI) treatment time by increasing sperm concentration. DESIGN We compared the ICSI treatment time required for porcine sperm using a method employing the microfluidic device and one using the conventional microdroplet method. SETTINGS Academic research laboratories at Okayama University. ANIMAL(S) Reproductive cells of porcine sperm, oocytes, and embryos. INTERVENTION(S) Cell manipulations, ICSI, and embryo culture. MAIN OUTCOME MEASURE(S) Average ICSI treatment time and sperm concentration. RESULT(S) The average ICSI treatment time (mean ± SEM) using the method with the microfluidic device for poor-quality semen (sperm concentration, 2.0 × 10(4) cells/mL) was significantly shorter than the treatment time using the conventional microdroplet method (265 ± 15 seconds [n = 43] vs. 347 ± 19 seconds [n = 50]). When diluted semen with a sperm concentration of 2.0 × 10(5) cells/mL was used, no significant difference was observed between the two methods (n = 50 and n = 48). CONCLUSION(S) The microfluidic device can reduce the time required for ICSI treatment that is used to increase sperm concentration in poor-quality semen samples. The results suggest that this device may be clinically useful for ICSI treatment in human assisted reproductive technology.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Microfluidic Device Increases Sperm Concentration by Optimization of Chamber Structure

Intracytoplasmic sperm injection (ICSI) is an extremely timeconsuming and tedious procedure in cases of oligozoospermia, because it is difficult to obtain a sufficient number of motile sperms. To circumvent this difficulty, we previously developed a microfluidic device to increase sperm concentration and reduce time required for ICSI. Here, we improved this device by carefully optimizing its di...

متن کامل

Screening of sperm velocity by fluid mechanical characteristics of a cyclo-olefin polymer microfluidic sperm-sorting device.

The microfluidic sperm-sorting (MFSS) device is a promising advancement for assisted reproductive technology. Previously, poly(dimethylsiloxiane) and quartz MFSS devices were developed and used for intracytoplasmic sperm injection. However, these disposable devices were not clinically suitable for assisted reproduction, so a cyclo-olefin polymer MFSS (COP-MFSS) device was developed. By micromac...

متن کامل

P-41: Evaluation of CAPZA3 Expression in Infertile Individuals Undergoing Intracytoplasmic Sperm Injection

Background: CAPZA3 is one of the actin-capping proteins believed to be play an important role in controlling of actin polymerization during spermiogenesis and has been shown to be peresent in mature sperm. Immunohistochemistry showed that human CAPZA3 is localized in the neck region of ejaculated sperm, with moderate and faint signals also detected in the tail and post-acrosome region respectiv...

متن کامل

Effects of Various Activators on Bovine Embryonic Development Following Intracytoplasmic Sperm Injection

The objective of this study was to compare the effectiveness of various combination activators of bovine oocyte following intracytoplasmic sperm injection (ICSI) in terms of cleavage and embryo development. Bovine ICSI oocytes were treated with a variation of treatments of combined or single activators as follows; 30 V for 15 x 2 μsec of electrical pulse +10 μg/mL cycloheximide (CHX),7% ethanol...

متن کامل

Evaluation of Ovarian Reserve by Measurement of the Serum Levels of Anti-Mullerian Hormone and Follicle-Stimulating Hormone in Intracytoplasmic Sperm Injection Cycles

Background It is important to evaluate ovarian reserves prior to intracytoplasmic sperm injection (ICSI) treatment. The aim of this study is to determine the accuracy of anti-mullerian hormone (AMH) as a marker for ovarian reserve and to compare it with day-3 serum follicle-stimulating hormone (FSH) levels. MaterialsAndMethods In this analytic, corss-sectional study, sequential sampling was don...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Fertility and sterility

دوره 99 2  شماره 

صفحات  -

تاریخ انتشار 2013