Cerebral oxygenation after birth – a comparison of INVOS® and FORE‐SIGHT™ near‐infrared spectroscopy oximeters
نویسندگان
چکیده
AIM To compare absolute values of regional cerebral tissue oxygenation (cStO2 ) during haemodynamic transition after birth and repeatability during steady state for two commercial near-infrared spectroscopy (NIRS) devices. METHODS In a prospective observational study, the INVOS 5100C and FORE-SIGHT were compared on 12 term newborns delivered by elective caesarean section. During the 10 min following umbilical cord clamping, cStO2 was measured simultaneously with the neonatal sensors from each device. Repeated measurements were taken the following day. RESULTS Three and 8 min after clamping, the mean cStO2 value increased from 53.4% (CI 36.8-69.9%) to 86.0% (CI 80.2-91.7%) for INVOS and from 61.6% (CI 55.4-67.8%) to 82.2% (CI 77.7-86.7%) for FORE-SIGHT. The Bland-Altman plot revealed decreasing difference (INVOS minus FORE-SIGHT) (D) in absolute values (A) with increasing cStO2 (D = 0.5A - 38.19 p = <0.001). The mean steady-state value on day two was 78.4% (CI 74.6-82.2%) and 86.2% (CI 85.0-87.4%) for INVOS and FORE-SIGHT, respectively. The within-subject standard deviation during steady-state repeated measurements was 4.8% ± 0.86 for INVOS and 2.8% ± 0.5 for FORE-SIGHT. CONCLUSION The INVOS and FORE-SIGHT cStO2 estimates showed oxygenation-level-dependent difference during birth transition. The better repeatability of FORE-SIGHT could be due to the lower response to change in saturation.
منابع مشابه
Impact of extracranial contamination on regional cerebral oxygen saturation: a comparison of three cerebral oximetry technologies.
BACKGROUND Cerebral oximetry is a noninvasive technology using near-infrared spectroscopy (NIRS) to estimate regional cerebral oxygen saturation. Although NIRS cerebral oximetry is being increasingly used in many clinical settings, interdevice technologic differences suggest potential variation in the ability to accurately acquire brain oxygenation signals. The primary objective of this study w...
متن کاملDirect comparison between cerebral oximetry by INVOSTM and EQUANOXTM during cardiac surgery: a pilot study
INTRODUCTION Several near-infrared spectroscopy oximeters are commercially available for clinical use, with lack of standardization among them. Accordingly, cerebral oxygen saturation thresholds for hypoxia/ischemia identified in studies conducted with INVOS(TM) models do not necessarily apply to other devices. In this study, the measurements made with both INVOS(TM) and EQUANOX(TM) oximeters o...
متن کاملDetection of critical cerebral desaturation thresholds by three regional oximeters during hypoxia: a pilot study in healthy volunteers
BACKGROUND Regional oximetry is increasingly used to monitor post-extraction oxygen status of the brain during surgical procedures where hemodynamic fluctuations are expected. Particularly in cardiac surgery, clinicians employ an interventional algorithm to restore baseline regional oxygen saturation (rSO2) when a patient reaches a critical desaturation threshold. Evidence suggests that monitor...
متن کاملFeasibility of absolute cerebral tissue oxygen saturation during cardiopulmonary resuscitation
INTRODUCTION Current monitoring during cardiopulmonary resuscitation (CPR) is limited to clinical observation of consciousness, breathing pattern and presence of a pulse. At the same time, the adequacy of cerebral oxygenation during CPR is critical for neurological outcome and thus survival. Cerebral oximetry, based on near-infrared spectroscopy (NIRS), provides a measure of brain oxygen satura...
متن کاملChanges in cerebral oxygenation during early postnatal adaptation in newborns delivered by vacuum extraction measured by near-infrared spectroscopy
BACKGROUND Newborns delivered by vacuum extraction quite often show clinical signs of a hemodynamic compromise, which is difficult to assess in terms of severity. The conventional means to measure the hemodynamic status are not sensitive enough to appreciate the severity of general, and more specifically of cerebral circulatory imbalance. The aim was to study cerebral tissue oxygenation during ...
متن کامل