Aspheric versus Spherical Posterior Chamber Intraocular Lenses
نویسندگان
چکیده
PURPOSE To compare spherical aberration and contrast sensitivity function following implantation of four different foldable posterior chamber intraocular lenses (IOLs), namely Sensar, Akreos AO, Tecnis, and AcrySof IQ. METHODS In this randomized clinical trial, 68 eyes of 68 patients with senile cataracts underwent phacoemulsification and IOL implantation with Sensar (n=17), Akreos AO (n=17), Tecnis (n=17), or AcrySof IQ (n=17). Uncorrected visual acuity (UCVA) and best spectacle-corrected visual acuity (BSCVA), spherical aberration and contrast sensitivity function (CSF) were compared among the study groups, 3 months after surgery. RESULTS There was no significant difference between the study groups in terms of age (P = 0.21). Mean postoperative BSCVA with Sensar, Akreos AO, Tecnis, and AcrySof IQ was 0.15±0.10, 0.12±0.9, 0.08±0.08, and 0.08±0.07 logMAR, respectively (P=0.08). Spherical aberration measured over a 4 mm pupil was significantly higher with Sensar and Akreos AO than the two other IOLs. The difference between Tecnis and AcrySof IQ was significantly in favor of the former IOL. Over a 6 mm pupil, spherical aberrations were comparable with Sensar and Akreos AO, furthermore spherical aberration was also comparable among eyes implanted with Akreos AO, AcrySof IQ, and Tecnis. Sensar yielded significantly inferior results as compared to Acrysof IQ and Tecnis. CSF with Sensar was inferior to the three aspheric IOLs at the majority of spatial frequencies. Tecnis yielded significantly better mesopic CSF at 1.5 and 3 cycles per degree spatial frequencies. CONCLUSION Tecnis and AcrySof IQ provided significantly better visual function as compared to Sensar and Akreos AO, especially with smaller pupil size. However, this difference diminished with increasing pupil size.
منابع مشابه
Visual Outcomes of Two Aspheric PCIOLs: Tecnis Z9000 versus Akreos AO
PURPOSE TO COMPARE SPHERICAL ABERRATION AND CONTRAST SENSITIVITY WITH TWO DIFFERENT TYPES OF ASPHERIC POSTERIOR CHAMBER INTRAOCULAR LENSES (PCIOLS): Tecnis Z9000 versus Akreos AO. METHODS Thirty-four eyes of 34 patients undergoing phacoemulsification for senile cataracts were randomly assigned to implantation of Tecnis Z9000 or Akreos AO PCIOLs. Outcome measures included best-corrected visual...
متن کاملComparison of higher order aberrations with spherical and aspheric IOLs compared to normal phakic eyes.
PURPOSE To compare higher order aberrations (HOA) in AcrySof SN60AT and Acrysof IQ SN60WF intraocular lenses (IOLs) and natural crystalline lenses in an age-matched population. METHODS Sixty-nine eyes of 55 patients were examined. Group I included AcrySof spheric lenses, group II AcrySof aspheric lenses, and group III included patients with the natural crystalline lens. The HOA data were obta...
متن کاملThe efficiency of aspheric intraocular lens according to biometric measurements
PURPOSE To analyze internal spherical aberration in pseudophakic eyes that underwent aspheric intraocular lens (IOL) implantation, and to investigate the relationships between biometric data and the effectiveness of aspheric IOL implantation. METHODS This retrospective study included 40 eyes of 40 patients who underwent implantation of an IOL having a negative spherical aberration of -0.20 μm...
متن کاملPosterior Capsule Opacification and Nd-YAG rates evaluation in a large series of pseudophakic cases
Purpose To evaluate the influence of Intraocular Lens (IOL) material and design on Posterior Capsule Opacification (PCO) and Neodymium-YAG (Nd-YAG) rates in eyes implanted with different Posterior Chamber Intraocular Lenses (PC IOLs) designs at the end of uncomplicated cataract surgeries. Setting Oculus Eye Clinic, Bucharest, Romania. Design Retrospective, observational study. Methods Thi...
متن کاملComparison of retinal image quality with spherical and customized aspheric intraocular lenses
We hypothesize that an intraocular lens (IOL) with higher-order aspheric surfaces customized for an individual eye provides improved retinal image quality, despite the misalignments that accompany cataract surgery. To test this hypothesis, ray-tracing eye models were used to investigate 10 designs of mono-focal single lens IOLs with rotationally symmetric spherical, aspheric, and customized sur...
متن کامل