Reduction of ring artefacts in high resolution micro-CT reconstructions.
نویسندگان
چکیده
High resolution micro-CT images are often corrupted by ring artefacts, prohibiting quantitative analysis and hampering post processing. Removing or at least significantly reducing such artefacts is indispensable. However, since micro-CT systems are pushed to the extremes in the quest for the ultimate spatial resolution, ring artefacts can hardly be avoided. Moreover, as opposed to clinical CT systems, conventional correction schemes such as flat-field correction do not lead to satisfactory results. Therefore, in this note a simple but efficient and fast post processing method is proposed that effectively reduces ring artefacts in reconstructed micro-CT images.
منابع مشابه
High-resolution helical cone-beam micro-CT with theoretically-exact reconstruction from experimental data.
PURPOSE In this paper we show that optimization-based autofocus may be used to overcome the instabilities that have, until now, made high-resolution theoretically-exact tomographic reconstruction impractical. To our knowledge, this represents the first successful use of theoretically-exact reconstruction in helical micro computed tomography (micro-CT) imaging. We show that autofocus-corrected, ...
متن کاملIs correction for metallic artefacts mandatory in cardiac SPECT/CT imaging in the presence of pacemaker and implantable cardioverter defibrillator leads?
Introduction: Metallic artifacts due to pacemaker/ implantable cardioverter defibrillator (ICD) leads in CT images can produce artifactual uptake in cardiac SPECT/CT images. The aim of this study was to determine the influence of the metallic artifacts due to pacemaker and ICD leads on myocardial SPECT/CT imaging. Methods: The study included 9 patients wh...
متن کاملAn improved method for the removal of ring artifacts in high resolution CT imaging
In high resolution computed tomography (CT) using flat panel detectors, imperfect or defected detector elements cause stripe artifacts in sinogram which results in concentric ring artifacts in the image. Such ring artifacts obscure image details in the regions of interest of the image. In this article, novel techniques are proposed for the detection, classification, and correction of ring artif...
متن کاملRing artefact in multidetector CT.
To cite: Artul S. BMJ Case Rep Published online: [please include Day Month Year] doi:10.1136/bcr-2013201379 DESCRIPTION High-resolution tomographic images acquired with a digital X-ray detector are often degraded by the so-called ring artefacts. Ring artefacts are the concentric rings superimposed on tomographic images. Artefacts in general can seriously degrade the quality of multidetector CT ...
متن کاملHigh‐resolution micro‐CT scanning as an innovative tool for evaluating dental hard tissue development
Microcomputerized tomography (micro-CT) allows discriminating very smal lchanges in dental hard tissue volumes. The aim of the present study was to create a new method for obtaining high-resolution, three-dimensional images of dental hard tissue development using micro-CT, and to observe the changes in dental hard tissue development and composition in growing rat pups. Tooth germs from rats at ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Physics in medicine and biology
دوره 49 14 شماره
صفحات -
تاریخ انتشار 2004