Annular height-to-commissural width ratio of annulolasty rings in vivo.
نویسندگان
چکیده
BACKGROUND A "saddle-shaped" mitral annulus with an optimal ratio between annular height and commissural diameter may reduce leaflet and chordal stress and is purported to be conserved across mammalian species. Whether annuloplasty rings maintain this relationship is unknown. METHODS AND RESULTS Twenty-three adult sheep underwent implantation of radiopaque markers on the left ventricle and mitral annulus. Eight animals underwent implantation of a Carpentier-Edwards Physio ring, 7 underwent a Medtronic Duran flexible ring, and 8 served as controls. Animals were studied with biplane videofluoroscopy 7 to 10 days postoperatively. Annular height and commissural width (CW) were determined from 3D marker coordinates, and annular height:CW ratio (AHWCR) was calculated. Annular height was similar in Control and Duran animals but significantly lower in the Physio group at end diastole (8.4+/-3.8, 6.7+/-2.3, and 3.4+/-0.6 mm, respectively, for Control, Duran, and Physio; ANOVA=0.005) and at end systole (14.5+/-6.2, 10.5+/-5.5, and 5.8+/-2.5 mm, respectively, for Control, Duran, and Physio; ANOVA=0.004). Both ring groups reduced CW significantly relative to Control. AHCWR did not differ between Control and Duran but was lower in Physio (23+/-11%, 24+/-7%, and 12+/-2% at end diastole and 42+/-17%, 37+/-17%, and 21+/-10% at end systole, respectively, for Control, Duran, and Physio, respectively; ANOVA <0.05 for both). CONCLUSIONS Mitral annular height and AHWCR of the native valve were unchanged by a Duran ring, whereas the Physio ring led to a lower AHWCR. Theoretically, such a flexible annuloplasty ring may provide better leaflet stress distribution by maintaining normal AHWCR.
منابع مشابه
Effect of annular shape on leaflet curvature in reducing mitral leaflet stress.
BACKGROUND Leaflet curvature is known to reduce mechanical stress. There are 2 major components that contribute to this curvature. Leaflet billowing introduces the most obvious form of leaflet curvature. The saddle shape of the mitral annulus imparts a more subtle form of leaflet curvature. This study explores the relative contributions of leaflet billowing and annular shape on leaflet curvatur...
متن کاملSaddle-shaped mitral valve annuloplasty rings experience lower forces compared with flat rings.
BACKGROUND New insight into the 3D dynamic behavior of the mitral valve has prompted a reevaluation of annuloplasty ring designs. Force balance analysis indicates correlation between annulus forces and stresses in leaflets and chords. Improving this stress distribution can intuitively enhance the durability of mitral valve repair. We tested the hypothesis that saddle-shaped annuloplasty rings h...
متن کاملThe unsaddled annulus: biomechanical culprit in mitral valve prolapse?
M asterful mitral valve (MV) repair demands thorough understanding of integrated mitral apparatus structure and mechanics. One consistently reported feature, the saddle shape of the mitral annulus, was recognized in the process of resolving the contradiction posed by an apparently high prevalence of MV prolapse (MVP) in otherwise healthy individuals: A normal saddle-like shape will show opposit...
متن کاملExperimental and Numerical Simulation Investigation on Crushing Response of Foam-Filled Conical Tubes Stiffened with Annular Rings
In this paper, crashworthiness characteristics of conical steel tubes stiffened by annular rings and rigid polyurethane foam are investigated. For this purpose, wide circumferential rings are created from the outer surface of the conical tube at some determined areas along tube length. In fact, this method divides a long conical tube into several tubes of shorter length. When this structure is ...
متن کاملFabrication and characterization of annular-array, high-frequency, ultrasonic transducers based on PZT thick film
In this work, low temperature deposition of ceramics, in combination with micromachining techniques have been used to fabricate a kerfed, annular–array, high–frequency, micro ultrasonic transducer (with seven elements). This transducer was based on PZT thick film and operated in thickness mode. The 27 μm thick PZT film was fabricated using a low temperature (720 oC) composite sol-gel ceramic (s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 112 9 Suppl شماره
صفحات -
تاریخ انتشار 2005