Registration strategies and similarity measures for three-dimensional ultrasound mosaicing.
نویسندگان
چکیده
RATIONALE AND OBJECTIVES The creation of two-dimensional (2D) ultrasound mosaics is becoming a common clinical practice with a high clinical value. The next step coming along with the increasing availability of 2D array transducers is the creation of three-dimensional mosaics. The correct alignment of multiple ultrasound images is, however, a complex task. In the literature of ultrasound registration, the alignment of two images has been often addressed, but not the alignment of multiple images. Therefore, we propose registration strategies for multiple image alignment and ultrasound specific similarity measures, which are able to cope with problems when aligning ultrasound images. MATERIALS AND METHODS In this study, we investigate the following strategies for multiple image alignment: pairwise registration with a successive Lie group normalization and simultaneous registration, which urges the usage of multivariate similarity measures. We propose alternative multivariate extensions for similarity measures based on a maximum likelihood framework. Moreover, we take the inherent contamination of ultrasound images by speckle patterns into consideration by using alternative noise models based on multiplicative Rayleigh distributed noise. This leads us to ultrasound-specific similarity measures. RESULTS We compare the performances of pairwise and simultaneous registration approaches for the mosaicing scenario. Bivariate similarity measures are highly overlap-dependent, so that they rather favor the total overlap of the images than their correct alignment. Using ultrasound-specific bivariate measures leads to better results; however, a local optimum at the total overlap remains. In contrast, the derived multivariate similarity measures have a clear and single optimum at the correct alignment of the volumes. CONCLUSION The experiments indicate that standard, pairwise registration techniques have problems by aligning multiple ultrasound images with partial overlap. We demonstrate that the usage of an ultrasound specific similarity measure leads to better results for pairwise registration. The highest robustness, however, can be achieved by using simultaneous registration with the developed multivariate similarity measures.
منابع مشابه
Ultrasound Specific Similarity Measures for Three-Dimensional Mosaicing
The introduction of 2D array ultrasound transducers enables the instantaneous acquisition of ultrasound volumes in the clinical practice. The next step coming along is the combination of several scans to create compounded volumes that provide an extended field-of-view, so called mosaics. The correct alignment of multiple images, which is a complex task, forms the basis of mosaicing. Especially ...
متن کاملThree-Dimensional Ultrasound Mosaicing
The creation of 2D ultrasound mosaics is becoming a common clinical practice with a high clinical value. The next step coming along with the increasing availability of 2D array transducers is the creation of 3D mosaics. In the literature of ultrasound registration, the alignment of multiple images has not yet been addressed. Therefore, we propose registration strategies, which are able to cope ...
متن کاملUltrasound Mosaicing and Motion Modeling - Applications in Medical Image Registration
The correct alignment of images is one of the key technologies in medical imaging. It allows for arranging images in a common reference frame and therefore to propagate complementary information between them. The process that calculates the transformation is referred to as registration. The automatic registration of images is important for several applications, with ultrasound mosaicing and mot...
متن کاملImage Registration and Mosaicing using a Self-Calibrating Camera
We introduce a new approach for the solution of three interrelated problems: Image registration, mosaicing and camera calibration. First we use well known similarity measures with particular interest in enhancing the performance for image registration. After initial registration we use a camera model to reene the alignment updating estimated camera parameters. A relaxation method applied on thi...
متن کاملEvaluation of Similarity Measures for Template Matching
Image matching is a critical process in various photogrammetry, computer vision and remote sensing applications such as image registration, 3D model reconstruction, change detection, image fusion, pattern recognition, autonomous navigation, and digital elevation model (DEM) generation and orientation. The primary goal of the image matching process is to establish the correspondence between two ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Academic radiology
دوره 15 11 شماره
صفحات -
تاریخ انتشار 2008