Potentiometric determination of dopamine in pharmaceutical preparations by crown ether-PVC membrane sensors.

نویسندگان

  • A M Othman
  • N M H Rizka
  • M S El-Shahawi
چکیده

Two simple, rapid and sensitive sensors for the assay of dopamine hydrochloride have been developed. The methods are based upon the formation of the membrane sensors 12-crown-4-phosphotungestic acid (crown ether-PTA)-dopamine and 12-crown-4-tetraphenylborate (crown ether-TPB)-dopamine as neutral carriers. The sensors were stable and showed fast potential responses of 10 s, and near-Nernstian cationic slopes of 53.3 - 56.2 mV/decade of activity between pH 2.2 - 6 for the monovalent dopamine cation over a wide range concentrations 1 x 10(-5) - 1 x 10(-1) M. The selectivity coefficients of the developed sensors indicated excellent selectivity for dopamine over a large number of organic and inorganic species and pharmaceutical excipients. The mediator o-nitrophenyloctyl ether significantly affected the lifetime of the fabricated sensors of dopamine. Satisfactory results were obtained for the determination of dopamine in dosage form by the proposed sensors with an average recovery of 99.85% for the nominal concentration.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance Evaluation of a Novel Potentiometric Membrane Sensor for Determination of Atorvastatin in Pharmaceutical Preparations

A novel potentiometric ion-selective PVC membrane sensor for analysis of atorvastatin (AT) in pharmaceutical preparations based on atorvastatin-(tetraphenyl borate), (AT-(TPB)2) as sensing element, tetraphenyl borate as additive and tris-2-ethyl-hexyl phosphate (TOP) as plasticizer solvent was prepared. The electrode shows a good Nernestian response over the concentration range of 0.09–5586 µ...

متن کامل

Performance Evaluation of a Novel Potentiometric Membrane Sensor for Determination of Atorvastatin in Pharmaceutical Preparations

A novel potentiometric ion-selective PVC membrane sensor for analysis of atorvastatin (AT) in pharmaceutical preparations based on atorvastatin-(tetraphenyl borate), (AT-(TPB)2) as sensing element, tetraphenyl borate as additive and tris-2-ethyl-hexyl phosphate (TOP) as plasticizer solvent was prepared. The electrode shows a good Nernestian response over the concentration range of 0.09–5586 µ...

متن کامل

Green Potentiometric Method for Determination of Triprolidine Hydrochloride and Pseudoephedrine Hydrochloride in their Different Pharmaceutical Matrices using Liquid and Solid Contact Gold Electrodes

Factors affecting the performance of polyvinyl chloride based ion selective electrode such as using different cationic exchangers and ionophores as well as sensor fabrication procedures were recently the scope of study by several researchers. This work presents an environment friendly electro-analytical method for the determination of Triprolidine HCl (TRI) and Pseudoephedrine HCl (PSE). A comp...

متن کامل

Potentiometric Determination of Ketotifen Fumarate in Pharmaceutical Preparations and Urine Using Carbon Paste and PVC Membrane Selective Electrodes

This study compares between unmodified carbon paste (CPE; the paste has no ion pair) and polyvinyl chloride (PVC) membrane selective electrodes that were used in potentiometric determination of ketotifen fumarate (KTF), where sodium tetraphenylborate (NaTPB) was used as titrant. The performance characteristics of these sensors were evaluated according to IUPAC recommendations which reveal a fas...

متن کامل

Development of novel potentiometric sensors for determination of lidocaine hydrochloride in pharmaceutical preparations, serum and urine samples

This article is focused on the determination of lidocaine hydrochloride as a local anaesthetic drug. A potentiometric method based on modified screen-printed and modified carbon paste ion-selective electrodes was described for the determination of lidocaine hydrochloride in different pharmaceutical preparations. It was based on potentiometric titration of lidocaine hydrochloride using modified ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 20 4  شماره 

صفحات  -

تاریخ انتشار 2004