Push-out tests on shear studs in high strength concrete
نویسندگان
چکیده
A lot of push-out tests of shear studs embedded in normal strength concrete were conducted. So current design code methods of the shear studs are based on the test results of studs embedded in normal strength concrete. It also appeared that the strength of connector and the concrete strength are the main factors affecting the behavior of shear connections. But push-out test data of studs embedded in high strength concrete is insufficient until currently. So it is necessary to evaluate the load-slip behavior and the shear capacity of studs embedded in high strength concrete for the appropriate design code. In this paper, it was performed push-out tests of shear studs embedded in high strength concrete and fiber reinforced concrete used widely in high-rise building. Experimental pushout tests were used to evaluate both the shear stud capacity and the load-slip curve of the connector. And the results of the finite element model are compared with push-out tests and the values given in current codes of practice.
منابع مشابه
Testing and numerical modelling of Steel-Concrete-Steel with stud bolts connectors subject to push-out loading
Steel-concrete-steel (SCS) sandwich panels are composed of two steel plates with low thicknesses and high densities and strengths and one thick layer between both plates with low strength and density known as core that is composed of concrete. Cohesive material-epoxy resin or shear connectors are usually used to connect the plates to the concrete core. SCS sandwich composites are being develope...
متن کاملEffect of type and distribution of shear studs on the behavior of composite steel-concrete shear walls
In this research in-plane shear Behavior of composite steel-concrete shear walls was investigated considering the Effects of steel plates thickness, spaces between shear studs, shape and type of shear studs and existing of minimum reinforcement in wall section. Several finite element models were analyzed and Numerical results of two models were taken under verification with existent experimenta...
متن کاملInnovative shear connection with composite dowels – verification using push-out test
In recent years many research on composite beams with innovative shear transmission with composite dowels have been conducted and innovative composite constructions have been built. One of the common types of shear connection is the method of rolled girders encased in a concrete slab. The combination of such method and pcb (precast composite beam) technology is called pcb-W (precast composite b...
متن کاملEffect of the Concrete Strength on the Concrete-Steel Bond in Concrete Filled Steel Tubes
In this study, the concrete-steel bond strength of concrete filled cylindrical steel tubes has been experimentally investigated. 22 short, high strength and normal concrete filled circular steel tubes were tested. Push-out test was carried out as the common method to evaluate the bond carrying capacity. Four different concrete mixes were used in preparing the specimens. The steel tubes were w...
متن کاملInfluences of Surface Characteristics and Modified Asphalt Binders on Interface Shear Strength
Weak bonding between layers of pavement leads to damages on the composite pavement. Bonding plays an important role in the durability and maintenance of composite pavement layers. The present study evaluates the factors effective in bond strength of the interface between concrete and asphalt pavements. The factors considered for this purpose include steel slag percentage in the concrete pavemen...