An in vitro assessment of the physical properties of novel Hyflex nickel-titanium rotary instruments.

نویسندگان

  • O A Peters
  • A K Gluskin
  • R A Weiss
  • J T Han
چکیده

AIM To determine several properties including torsional and fatigue limits, as well as torque during canal preparation, of Hyflex, a rotary instrument manufactured from so-called controlled memory nickel-titanium alloy. METHODOLOGY The instruments were tested in vitro using a special torque bench that permits both stationary torque tests according to ISO3630-1 and fatigue limit determination, as well as measurement of torque (in Ncm) and apical force (in N) during canal preparation. Fatigue limit (in numbers of cycles to failure) was determined in a 90°, 5 mm radius block-and-rod assembly. Simulated canals in plastic blocks were prepared using both a manufacturer-recommended single-length technique as well as a generic crown-down approach. anova with Bonferroni post hoc procedures was used for statistical analysis. RESULTS Torque at failure ranged from 0.47 to 1.38 Ncm, with significant differences between instrument sizes (P < 0.0001). Fatigue life ranged from 260 to 2565, with the shortest and longest lifespan for instruments size 20, .04 taper and size 25, .08 taper, respectively. Torque during canal preparation was significantly higher for small instruments used in the single-length technique but lower for the size 40, .04 taper, compared to a crown-down approach. No instrument fractured; 82% of the instruments used were plastically deformed; however, only 37% of these remained deformed after a sterilization cycle. CONCLUSIONS Hyflex rotary instruments are bendable and flexible and have similar torsional resistance compared to instruments made of conventional NiTi. Fatigue resistance is much higher, and torque during preparation is less, compared to other rotary instruments tested previously under similar conditions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An in vitro comparison of apically extruded debris and instrumentation times with ProTaper Universal, ProTaper Next, Twisted File Adaptive, and HyFlex instruments.

INTRODUCTION The purpose of this study was to compare the in vitro amount of apically extruded debris with new endodontic rotary nickel-titanium instruments. METHODS Sixty mandibular premolars were instrumented up to size 25 using ProTaper Universal (Dentsply Maillefer, Ballaigues, Switzerland), ProTaper Next (Dentsply Maillefer), Twisted File Adaptive (SybronEndo, Orange, CA), and HyFlex (Co...

متن کامل

Bending properties of a new nickel-titanium alloy with a lower percent by weight of nickel.

INTRODUCTION The aim of the present study was to evaluate the bending properties of Hyflex instruments, which exhibit a lower percent in weight of nickel (52 Ni %wt) and compare them with other commercially available nickel-titanium (NiTi) rotary instruments. METHODS Ten instruments with tip size 25, 0.06 taper of each of the following NiTi rotary instrumentation techniques were selected for ...

متن کامل

An in-vitro Evaluation of canal transportation and centering ability of two rotary Nickel Titanium systems (Twisted Files and Hyflex files) with conventional stainless Steel hand K-flexofiles by using Spiral Computed Tomography.

BACKGROUND The purpose of this in-vitro study was to compare canal transportation and centering ability of Twisted and Hyflex Rotary Files with stainless steel hand k-flexofiles by using Spiral Computed Tomography. MATERIALS & METHODS A total of 90 freshly extracted human mandibular single rooted Premolar teeth were selected. The crowns were flattened with steel disks and a final dimension of...

متن کامل

Cleaning Effectiveness of Three NiTi Rotary Instruments: A Focus on Biomaterial Properties

Nickel-titanium (NiTi) instruments are commonly used for shaping the root canal system in endodontic practice. They are more flexible and have better cutting efficiency than conventional stainless steel files. The superelasticity of NiTi rotary files allows the clinicians to produce the desirable tapered root canal form with a reduced tendency to canal transportation and instrument fracture. Hy...

متن کامل

Comparison of preparation of curved root canals with Hyflex CM and Revo-S rotary nickel-titanium instruments.

AIM To compare the shaping ability of three different nickel-titanium rotary instruments during the preparation of curved root canals in extracted teeth. METHODOLOGY A total of 60 root canals with curvatures ranging between 25° and 35° were divided into three groups of 20 canals. Based on radiographs taken prior to instrumentation, the groups were balanced with respect to the angle and the ra...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International endodontic journal

دوره 45 11  شماره 

صفحات  -

تاریخ انتشار 2012