The efficacy of upper arm placement of peripherally inserted central catheters using bedside ultrasound and microintroducer technique.

نویسندگان

  • Inez Nichols
  • James P Humphrey
چکیده

In one hospital in southern Georgia, the review and analysis of 500 peripherally inserted central catheter procedural attempts by designated, specialty nurses using microintroducer technique and ultrasound guidance revealed an overall catheter placement success rate of 94.6%. This research analysis also provided information on the disposition of those 6-French dual-lumen and triple-lumen, power-injectable peripherally inserted central catheters actually placed in situ on subjects who remained hospitalized or within the hospital's rehabilitation facility. Of the 422 catheters removed, none exhibited signs or symptoms of mechanical phlebitis, and one tested positive per laboratory analysis for organisms confirming infection.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Missing Guide Wire After Placement of Peripherally Inserted Central Venous Catheter

BACKGROUND Central venous catheterization is a common tool used in critically ill patients to monitor central venous pressure and administer fluids and medications such as vasopressors. Here we present a case of a missing guide wire after placement of peripherally inserted central catheter (PICC), which was incidentally picked up by bedside ultrasound in the intensive care unit.  CASE REPORT A ...

متن کامل

A randomized, controlled trial evaluating postinsertion neck ultrasound in peripherally inserted central catheter procedures.

OBJECTIVE Insertion of peripherally inserted central catheters (PICCs) at the bedside may result in tip malposition. This study was designed to evaluate whether the addition of ultrasound (US) inspection of the ipsilateral neck provides immediate recognition of PICCs in aberrant position facilitating catheter reposition before completion of the procedure. DESIGN Randomized, controlled trial. ...

متن کامل

55-61 Botella:03 Di Cosmo

© SINPE-GASAPE ABSTRACT: A central venous access is needed in most patients who are candidates for parenteral nutrition. The technology of these devices has changed considerably since their initial use, one of the most recent trends being the delivery of parenteral nutrition through a peripherally inserted central catheter. Usually composed of silicone elastomer or secondor third-generation pol...

متن کامل

Effect of using static ultrasound technique on peripherally inserted central catheters’ insertion success rate in neonates in a neonatal intensive care unit

BACKGROUND Peripheral insertion of central catheters can be difficult in neonates. We compared the success rates of peripherally inserted central catheters by two methods of using static ultrasound and traditional technique (vein visualization and palpation) in neonates. MATERIALS AND METHODS In a prospective randomized, controlled trial, 52 neonates with birth weight lower than 1500 g in a l...

متن کامل

Ultrasound guided infraclavicular axillary vein cannulation, coming of age.

In this month’s journal Ahn and colleagues report the effect of arm abduction on the success of central catheter placement after ultrasound guided infraclavicular axillary vein (AXV) cannulation. We discuss these findings and reflect on the development of this particular route of access to central veins. This paper presents good evidence that arm abduction increases the success of central cathe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of infusion nursing : the official publication of the Infusion Nurses Society

دوره 31 3  شماره 

صفحات  -

تاریخ انتشار 2008