Modelization of the EOS

نویسنده

  • C. Fuchs
چکیده

This article summarizes theoretical predictions for the density and isospin dependence of the nuclear mean field and the corresponding nuclear equation of state. We compare predictions from microscopic and phenomenological approaches. An application to heavy ion reactions requires to incorporate these forces into the framework of dynamical transport models. Constraints on the nuclear equation of state derived from finite nuclei and from heavy ion reactions are discussed. PACS. 21.65.+f – 21.60.-n – 21.30.-x – 24.10.Cn – 25.75.-q – 25.60.Gc – 25.70.Mn

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Modeling and Simulation of Nucleate Boiling

This work investigates the modelization and simulation of liquid-vapor phase change in compressible flows. Each phase is modeled as a compressible fluid equipped with its own Equation of State (EOS). We suppose that inter-phase equilibrium processes in the medium operate at a short timescale compared to the other physical phenomena such as convection or thermal diffusion. This assumption provid...

متن کامل

A Comparison of Patients Absorption Doses with Bone Deformity Due to the EOS Imaging and Digital Radiology

  Background: This study has aimed to measure the patient dose in entire spine radiography by EOS system in comparison with the digital radiography. Methods: EOS stereo-radiography was used for frontal and lateral view spine imaging in 41 patients in a prospective analytical study. A calibrated dose area product (DAP) meter was used for calibration of the DAP in EOS system. The accuracy and pr...

متن کامل

Application of Carnahan-Starling-vdW-β Equation of State for Refrigerant Fluids

Herein, the application of Carnahan-Starling-vdW-β equation of state (EoS) for 13 refrigerant fluids was investigated. The EoS could predict the saturated liquid densities of these refrigerants over the temperature range of 100-400 K and pressures from zero up to187 MPa with the average absolute deviations of 2.66%. The accuracy of Carnahan-Starling-vdW-β EoS in liquid density prediction was al...

متن کامل

Comparison of entrance skin dose in the hip region in the imaging of the lower extremity by CT scan and EOS

Introduction: Increasing in refer to computed tomography (CT-scan) imaging causes to increase in cumulative dose. Stereoradiography (EOS) is an X-ray imaging technology that, by eliminating scattering radiation, reduces patient's absorption dose and improves image quality.   Materials and Methods: This cross-sectional study was carried out in a hosp...

متن کامل

Patient absorbed dose comparison in CT and Stereoradiography (EOS) imaging during lower limb torsion evaluation using in-vivo and in-vitro dosimetry methods

Introduction: Accurate evaluation of femoral and tibial torsion is essential for children or adult with legs deformity, becuse incorrect legs morphogenesis can lead to pathological situation. CT scan is commonly used for the measurement of skeletal bone parameters. But, disability in imaging from standing and sitting posture and absorb dose of patients are deficits of this meth...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005