Monitoring Fetal Heart Rate during Labor: A Comparison of Three Methods
نویسندگان
چکیده
The purpose of the study was to compare the accuracy of a noninvasive fetal heart rate monitor with that of ultrasound, using a fetal scalp electrode as the gold standard, in laboring women of varying body habitus, throughout labor and delivery. Laboring women requiring fetal scalp electrode were monitored simultaneously with the investigational device (noninvasive fetal ECG), ultrasound, and fetal scalp electrode. An algorithm extracted the fetal heart rate from the noninvasive fetal ECG signal. Each noninvasive device recording was compared with fetal scalp electrode with regard to reliability by positive percent agreement and accuracy by root mean squared error. Seventy-one women were included in this analysis. Positive percent agreement was 83.4 ± 15.4% for noninvasive fetal ECG and 62.4 ± 26.7% for ultrasound. The root mean squared error compared with fetal scalp electrode-derived fetal heart rate was 4.8 ± 2.0 bpm for noninvasive fetal ECG and 14.3 ± 8.2 bpm for ultrasound. The superiority of noninvasive fetal ECG was maintained for stages 1 and 2 of labor and increases in body mass index. Compared with fetal scalp electrode-derived fetal heart rate, noninvasive fetal ECG is more accurate and reliable than ultrasound for intrapartum monitoring for stages 1 and 2 of labor and is less affected by increasing maternal body mass index. This confirms the results of other workers in this field.
منابع مشابه
P-184: Investigation of Electronic Fetal Monitoring Application during Labor with Cesarean Section and Apgar Score
Background: Electronic fetal monitoring was used in many hospitals before labor and during delivery . The objective of this study was to investigate whether the use of fetal monitoring had effect on neonatal outcomes and cesarean section rate. Materials and Methods: A prospective study on monitoring neonatal Apgar and kind of delivery data, from deliveries occurring at Shahid Sadughi hospital i...
متن کاملارتباط احساس کاهش حرکت جنین توسط مادر حامله ترم با میزان عوارض جنین در طی زایمان
Introduction: The maternal perception of fetal movements at term has been used as an evaluative test of fetal wellbeing since the last 30 years, but there are different reports about its value. The aim of this study was evaluation of decreased fetal movement and relation to situation of fetus in uterus. It is significant that we understand the relationship between decreased fetal movement and i...
متن کاملIntrapartum heart rate ambiguity: a comparison of cardiotocogram and abdominal fetal electrocardiogram with maternal electrocardiogram.
OBJECTIVE/AIMS To investigate the presence of signal ambiguity of intrapartum fetal heart rate (FHR) monitoring during delivery by comparing simultaneous cardiotocogram (CTG), abdominal fetal electrocardiogram (ECG) with continuous maternal ECG. METHODS A total of 144 simultaneous CTG (Corometrics 250 series), abdominal fetal ECG (Monica -AN24™) and maternal ECG (Monica AN24™) recordings were...
متن کاملApparatus for Continuous Monitoring of the Fetal Heart Rate *
APPARATUS FOR CONTINUOUS MONITORING OF THE FETAL HEART RATE.* By Edward H. Hon, Department of Obstetrics and Gynecology, Yale University School of Medicine. During the past four years continuous monitoring of fetal heart rate during labor and delivery has permitted the accumulation of accurate, permanent records which may be of value for the assessment of fetal heart rate as an index of fetal e...
متن کاملInterpretation of the electronic fetal heart rate during labor.
Electronic fetal heart rate monitoring is commonly used to assess fetal well-being during labor. Although detection of fetal compromise is one benefit of fetal monitoring, there are also risks, including false-positive tests that may result in unnecessary surgical intervention. Since variable and inconsistent interpretation of fetal heart rate tracings may affect management, a systematic approa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
دوره 2017 شماره
صفحات -
تاریخ انتشار 2017