The use of high-resolution magnetic resonance imaging for monitoring interbody fusion and bioabsorbable cages: an ex vivo pilot study.
نویسندگان
چکیده
OBJECT Interbody fusion is a gradual process of graft resorption and tissue formation, ideally resulting in a bone bridge between two adjacent vertebral bodies. Initially, fibrous tissue and cartilage are formed, which subsequently are replaced by bone through the process of endochondral ossification. When cages and/or their contents are made of resorbable polymers like lactic or glycolic acids, there is a simultaneous process of implant degradation, which is eventually accompanied by reactions in the surrounding tissues. The purpose of this study was to explore the use of highresolution magnetic resonance (MR) imaging for monitoring tissue differentiation, spinal fusion, cage degradation, and eventually tissue reactions as a function of time. METHODS Lumbar vertebral segments obtained in 14 goats with 3, 6, and 12 months of follow up (three, four, and seven animals, respectively) were available from a study of the feasibility of poly(L,D-lactic acid) cages for spinal fusion. Plain x-ray films, MR images, and histological sections were used to evaluate spinal fusion and cage resorption. The first follow-up tests revealed that MR imaging noninvasively provided three-dimensional information on cage placement, cage degradation and bone formation, and that it has potential to differentiate between the various soft tissues. CONCLUSIONS Although the magnetic field strength and thus the resolution used were higher than normal in clinical practice, MR imaging appears to be a promising modality for the noninvasive clinical follow up of patients who undergo fusion with resorbable cages. Tissue reactions were not encountered in this study, and thus could not be evaluated.
منابع مشابه
Comparison of outcomes and safety of using hydroxyapatite granules as a substitute for autograft in cervical cages for anterior cervical discectomy and interbody fusion
Background: After cervical discectomy, autogenetic bone is packed into the cage to increase the rate of union between adjacent vertebral bodies, but donor site–related complications can still occur. In this study we evaluate the use of hydroxyapatite granules as a substitute for autograft for interbody fusion. Methods: From November 2008 to November 2011, 236 patients participated in ...
متن کاملThree-year follow-up of bioabsorbable PLLA cages for lumbar interbody fusion: in vitro and in vivo degradation.
Introduction: Current cage devices considerably exceed the stiffness of the spinal segment, which may lead to stress-shielding, migration of the cage, and pseudarthrosis. In order to avoid these material related complications, a poly (L-lactic acid) cage device (PLLA cage) has been designed with limited stiffness compared to current cage devices and which will be absorbed on the long term. Biom...
متن کاملApplication of Magnetic Resonance Imaging (MRI) as a safe & Application of Magnetic Resonance Imaging (MRI) as a safe & non-destructive method for monitoring of fruit & vegetable in postharvest period
To investigate and control quality, one must be able to measure quality-related attributes. Quality of produce encompasses sensory attributes, nutritive values, chemical constituents, mechanical properties, functional properties and defects. MRI has great potential for evaluating the quality of fruits and vegetables. The equipment now available is not feasible for routine quality testing. The ...
متن کاملBioabsorbable self-retaining PLA/nano-sized β-TCP cervical spine interbody fusion cage in goat models: an in vivo study
STUDY DESIGN This is an experimental animal study. OBJECTIVE The objective of this study was to compare an anterior cervical discectomy and interbody fusion of a novel polylactide/nano-sized β-tricalcium phosphate (PLA/nβ-TCP) bioabsorbable self-retaining cervical fusion cage (BCFC) with an autologous bone graft and polyetheretherketone (PEEK) cages. BACKGROUND Although PLA cervical cages h...
متن کاملAn investigation into the effect of magnetic resonance imaging (MRI) echo time spacing and number of echoes on the sensitivity and dose resolution of PAGATUG polymer-gel dosimeter
Background: There are various methods to read out responses of a polymer-gel dosimeter, among which the Magnetic Resonance Imaging (MRI) technique is the most common one. Optimizing imaging protocols can have significant effect on the sensitivity and the dose resolution of polymer gel dosimeters. This study has investigated the effects of the number of echoes (NOE) and the echo time spacing (ES...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Neurosurgical focus
دوره 16 3 شماره
صفحات -
تاریخ انتشار 2004