Accuracy of Single-Step versus 2-Step Double-Mix Impression Technique

نویسندگان

  • Eduardo Batista Franco
  • Leonardo Fernandes da Cunha
  • Francyle Simões Herrera
  • Ana Raquel Benetti
چکیده

Objective. To investigate the accuracy of dies obtained from single-step and 2-step double-mix impressions. Material and Methods. Impressions (n = 10) of a stainless steel die simulating a complete crown preparation were performed using a polyether (Impregum Soft Heavy and Light body) and a vinyl polysiloxane (Perfectim Blue Velvet and Flexi-Velvet) in two consistencies, in one or two (without relief) steps. Accuracy of the stone dies was accessed at a measuring microscope, using a metallic crown with perfect fit to the reference crown preparation. Data were submitted to 2-way ANOVA and Tukey test (α = 0.05). Results. The single-step technique resulted in slightly larger dies, while the 2-step technique without relief produced significantly smaller dies, when compared to the original stainless steel die. Stone dies obtained from 2-step polyether impressions were significantly smaller when compared to dies obtained from 2-step vinyl polysiloxane impressions (Impregum 2-step: -290.94 ± 71.64 μm; Perfectim 2-step: -201.86 ± 28.58 μm). No significant differences were observed in dies obtained from either polyether or vinyl polysiloxane with the single-step technique (Impregum single-step: 63.52 ± 16.60 μm; Perfectim single-step: 79.40 ± 14.11 μm). Conclusion. Higher discrepancies were detected for the 2-step impression technique without relief for the investigated materials.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative evaluation of dimensional accuracy of different polyvinyl siloxane putty-wash impression techniques-in vitro study.

BACKGROUND Dimensional accuracy when making impressions is crucial to the quality of fixed prosthodontic treatment, and the impression technique is a critical factor affecting this accuracy. The purpose of this in vitro study was to compare the dimensional accuracy of the casts obtained from one step double mix, two step double mix polyvinyl siloxane putty- wash impression techniques using thre...

متن کامل

Dimensional accuracy of three impression materials by one-step and two-step impression techniques: An in vitro study

Introduction: An accurate impression is essential to create a well-fitted dental prosthesis. This study aimed to compare the dimensional accuracy of three elastomeric materials using one-step and two-step impression techniques. Methods: In this study, 20 impressions were fabricated for each Vinyl siloxane ether (Identium), condensation silicone (Speedex), and a...

متن کامل

Dimensional Accuracy of Polyvinyl Siloxane Impression Materials Considering Impression Techniques– A Literature Review

Objectives Impression accuracy is the main determinant of the fit, form and function of prosthetic restorations. Polyvinyl siloxane (PVS) is the material of choice in most clinical situations. The purpose of this paper is to provide an up-to-date review of scientific articles which discuss the dimensional accuracy of PVS impression material using various impression techniques, tray types and sp...

متن کامل

The dimensional accuracy of polyvinyl siloxane impression materials using two different impression techniques: An in vitro study

AIM OF THE STUDY To evaluate and compare the linear dimensional changes of the three representative polyvinyl siloxane (PVS) impression materials and to compare the accuracy of single mix with double mix impression technique. METHODOLOGY A study mold was prepared according to revised American Dental Association specification number 19 for nonaqueous elastic dental impression materials. Three ...

متن کامل

Dimensional accuracy of 3 silicone dental impression materials.

This study was carried out to measure the dimensional changes in silicone impression material, which can affect the fitness of the prosthesis. Using both single and double mix techniques, 20 impression samples for each of 3 different proprietary silicones, Xantopren-H, President and Fulldent, were made. Selected measurements were made on the stone casts made from each impression. In all 3 cases...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2011  شماره 

صفحات  -

تاریخ انتشار 2011