Comparison of direct and indirect methods of measuring airborne chrysotile fibre concentration.

نویسندگان

  • Celine Eypert-Blaison
  • Sylvie Veissiere
  • Olivier Rastoix
  • Edmond Kauffer
چکیده

Transmission electron microscopy observations most frequently form a basis for estimating asbestos fibre concentration in the environment and in buildings with asbestos-containing materials. Sampled fibres can be transferred to microscope grids by applying either a direct [ISO (1995) Draft International ISO/DIS 10312. Ambient air. Determination of asbestos fibres. Direct transfer transmission electron microscopy procedure. Geneva, Switzerland: International Standardization Organization] or an indirect [AFNOR (1996) Détermination de la concentration en fibres d'amiante par microscopie électronique à transmission-Méthode indirecte. Cedex, France: AFNOR, p. 42; ISO (1997) Draft International ISO/DIS 13794. Ambient air. Determination of asbestos fibres. Indirect-transfer transmission electron microscopy procedure. Geneva, Switzerland: International Standardization Organization] method. In the latter case, ISO Standard 13794 recommends filtering calcination residues either on a polycarbonate (PC) filter (PC indirect method) or on a cellulose ester (CE) membrane (CE indirect method). The PC indirect method requires that fibres deposited on a PC filter be covered by a carbon layer, whereas in the CE indirect method, the CE membrane has to be directly processed using a method described in ISO Standard 10312. The purpose of this study was to compare results obtained using, on the one hand, direct preparation methods and, on the other hand, PC indirect or CE indirect methods, for counting asbestos fibres deposited on filters as a result of liquid filtration or air sampling. In direct method-based preparation, we observed that an etching time of 6-14 min does not affect the measured densities, except for fibres <1 microm deposited by liquid filtration. Moreover, in all cases, the direct method gives higher densities than the PC indirect method because of possible fibre disappearance when using the carbon evaporator implemented in the PC indirect method. The CE membrane used for sample preparation in the CE indirect method is collapsed prior to passing it through the carbon evaporator, so the fibres are less likely to disappear at this stage. We then note that the resulting fibre densities for chrysotile-loaded filters prepared using the direct method are close to those obtained with filters prepared using the CE indirect method. Our study therefore shows that, under the implemented experimental conditions, the PC and CE indirect preparation methods described in ISO Standard 13794 are not equivalent.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Airborne inorganic fibre level monitoring by transmission electron microscope (TEM): comparison of direct and indirect sample transfer methods.

The direct and indirect sample transfer techniques for measuring airborne inorganic fibres concentrations were studied by TEM for airborne rockwool fibres, chrysotile, amosite and tungsten oxide whiskers. The number and mass concentrations of fibres with aspect ratios > or = 5, prepared by these two techniques for fibres longer than 0.5 mu m and 5 mu m, and the aspect ratios were evaluated and ...

متن کامل

Size and shape of airborne asbestos fibres in mines and mills.

There is increasing evidence that fibre size and shape play an important part in the production of health effects related to asbestos. The dimensions of airborne fibres collected at various stages of fibre processing in three mines and six mills producing three types of asbestos were measured using phase contrast light microscopy and transmission electron microscopy. Airborne fibres of differen...

متن کامل

The use of a new static device based on the collection of the thoracic fraction for the assessment of the airborne concentration of asbestos fibres by transmission electron microscopy.

A new static device, the CATHIA sampling head, based on the collection of the thoracic fraction is proposed for the assessment of the airborne concentration of asbestos fibres by transmission electron microscopy. By comparison with a standard aerosol sampling head, it has been shown that this sampler reduces the total mass concentration, but does not introduce any change in the most common inde...

متن کامل

مطالعه غلظت و نوع الیاف آزبست با روش میکروسکوپی فاز کنتراست و الکترونی روبشی به منظور تعیین مواجهه شغلی در یک صنعت سیمان- آزبست

  Background and aims : Asbestos minerals are divided into two main groups including serpentine and amphiboles and each has one or more subgroups. These minerals have been used in industrial products such as cement-asbestos sheet and pipe, brake shoe, clutch and insulation materials. Occupational and non - occupational exposures by this carcinogenic material have caused to develop several metho...

متن کامل

Comparison of fibre types and size distributions in lung tissues of paraoccupational and occupational cases of malignant mesothelioma.

The results of analysis of mineral fibres in lung tissues from 10 paraoccupational cases of malignant mesothelioma were compared with analysis obtained from seven cases of malignant mesotheliomas that had developed in gas mask workers. Nine of the paraoccupational cases were considered to have developed their tumours because of exposure to asbestos on their husbands' working clothes and one can...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Annals of occupational hygiene

دوره 54 1  شماره 

صفحات  -

تاریخ انتشار 2010