Ultrasound Scatterer Size Estimation Technique Based on a 3d Acoustic Impedance Map from Histologic Sections

نویسندگان

  • Jonathan Mamou
  • Michael L. Oelze
  • James F. Zachary
  • William D. O’Brien
چکیده

Identifying the scatterers and obtaining accurate estimates of ultrasonic scatterer sizes are beneficial adjuncts to characterize (diagnose) disease from ultrasonic backscatterer measurements. A new scatterer size estimation technique has been developed that is based on a 3D acoustic impedance map. Ultrasonic scatterer estimation techniques rely extensively on form factor functions to obtain estimates, and 3D impedance maps can be used to derive independently form factors. The 3D acoustic impedance map is derived from a 3D histological data set of tissue, and is independent of ultrasonically acquired data. A rat fibroadenoma and a mouse 4T1 mouse mammary tumor (MMT) were fixed (10% neutral-buffered formalin), embedded in paraffin, serially sectioned at 10 and 5 respectively, and stained with H&E for histologic evaluation. Each section was digitally photographed through the light microscope. Tissue structures in each section were assigned distinct acoustic impedance values. The images from serial sections were aligned to yield two 3D impedance data set. A Gaussian form factor was used to estimate scatterer size and acoustic concentration. The scatterer size estimates were compared to previous values that were obtained from ultrasonic backscatterer measurements (also using a Gaussian form factor). For both 3D impedance maps, the relative difference between the size estimates were below 10%. The optimization scheme was also conducted on two simulated medium and led to relative errors below 1% for the scatterer size. This approach demonstrates that the use of 3D impedance maps has significant potential for improving parametric imaging by evaluating form factor functions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Identifying ultrasonic scattering sites from three-dimensional impedance maps.

Ultrasonic backscattered signals contain frequency-dependent information that is usually discarded to produce conventional B-mode images. It is hypothesized that parametrization of the quantitative ultrasound frequency-dependent information (i.e., estimating scatterer size and acoustic concentration) may be related to discrete scattering anatomic structures in tissues. Thus, an estimation techn...

متن کامل

Three-dimensional Acoustic Tissue Model: a Computational Tissue Phantom for Image Analyses

A novel methodology to obtain three-dimensional (3D) acoustic tissue models (3DATMs) is introduced. 3DATMs can be used as computational tools for ultrasonic imaging algorithm development and analysis. In particular, 3D models of biological structures can provide great benefit to better understand fundamentally how ultrasonic waves interact with biological materials. As an example, such models w...

متن کامل

Three-dimensional impedance map analysis of rabbit liver.

Three-dimensional impedance maps (3DZMs) are computational models of acoustic impedance of tissue constructed from histology images. 3DZMs can be analyzed to estimate model-based quantitative ultrasound parameters such as effective scatterer diameter (ESD). In this study, 3DZMs were constructed from normal and fatty rabbit livers. Estimates of ESD were made using the fluid-filled sphere scatter...

متن کامل

Three - Dimensional Impedance Map Analysis of Biological Tissue To

Three-dimensional impedance maps (3DZMs) are computational models of acoustic impedance of tissue constructed from a series of adjacent histology images. The power spectrum of a 3DZM can be analyzed to estimate model-based quantitative ultrasound parameters such as effective scatterer diameter (ESD) and effective acoustic concentration (EAC). The goal in this approach is to determine a link bet...

متن کامل

Estimation of Flow Zone Indicator Distribution by Using Seismic Data: A Case Study from a Central Iranian Oilfield

Flow unit characterization plays an important role in heterogeneity analysis and reservoir simulation studies. Usually, a correct description of the lateral variations of reservoir is associated with uncertainties. From this point of view, the well data alone does not cover reservoir properties. Because of large well distances, it is difficult to build the model of a heterogenic reservoir, but ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003