The Analytical Goals for Hemoglobin A1c Measurement in IFCC Units and National Glycohemoglobin Standardization
نویسندگان
چکیده
The variation of a biological measurand can be expressed in the units of the measured concentrations or as a percentage of the absolute variation relative to the mean concentration. For example, given that different metrologic systems are in use for the measurement of human body temperature, this parameter can be expressed in degrees Celsius (Europe), degrees Fahrenheit (US), or degrees Kelvin (scientists). The equivalent unitary variation is 1.0 °C, 1.8 °F, or 1.0 K, respectively. Expressed as a percentage of the mean body temperature, this variation corresponds to 2.7% (1/37 100) for degrees Celsius, 1.8% (1.8/99 100) for degrees Fahrenheit, and 0.3% (1/ 310 100) for degrees Kelvin. From these results, one might conclude that temperature variation is lowest for scientists and highest for Europeans. Of course, that is nonsense. This wrong conclusion derives from the fact that variation across metrologic systems cannot merely be compared in terms of relative percentages when the y intercept (b) in the generic conversion equation (y ax b) is not equal to zero. A higher y-intercept value will have a greater impact, as is illustrated by the example of the temperatures, where °F 1.8 °C 32, and K °C 273. These mathematical considerations related to temperatures in different units also apply in laboratory medicine when the results of one measurement system are converted to another according to a conversion equation (i.e., y ax b) in which the y intercept is not equal to zero. From the analytical point of view, a y intercept substantially different from zero usually reflects a difference in specificity between the 2 systems. Hemoglobin A1c (Hb A1c) 1 is a typical example. The “master equation” for converting to National Glycohemoglobin Standardization Program/ Diabetes Control and Complications Trial (NGSP/DCCT) results from the IFCC results is: NGSP/ DCCT (0.0915 IFCC) 2.15, where the positive y-intercept value reflects the different specificity of the NGSP/DCCT method (the “Hb A1c” peak after chromatography with Bio-Rex 70 resin contains about 2% coeluting non–Hb A1c hemoglobin fractions, including Hb F and carbamylated hemoglobin) (1 ). The implication is that the expression of biological variation as a CV will be different, depending on the unit of measure used (IFCC, millimoles per mole; NGSP/DCCT, percentage). In addition, given that biological variation is the basis for their derivation, the widths of reference intervals, the allowable analytical goals, and the interpretation of serial measurements will differ when the concept of reference change value is used. This consideration is summarized in Table 1. Biological variation, derived reference intervals, and analytical goals (based on either biological variation or outcome) are expressed in measurement units and as a relative percentage of the measured amounts. Data regarding the biological variation in Hb A1c vary in the literature (2 ). In the context of this Letter, however, which experimental data are selected is not relevant. For our example, we have chosen data published by Rohlfing et al. (3 ). As measured in NGSP units, they found values for intraindividual and interindividual Hb A1c variation (expressed as the SD) of 0.08% and 0.20%, respectively. Dividing these values by the mean of the measured Hb A1c values (4.90%), one obtains the corresponding intraindividual CV (CVI) and interindividual CV (CVG) values of 1.6% (0.08/4.90 100) and 4.1% (0.20/4.90 100), respectively. In IFCC units, the corresponding intraindividual variation (SD) is 0.88 mmol/mol (2.9% as the CVI), and the interindividual variation is 2.20 mmol/ mol (7.3% as the CVG). According to the mathematical premises described above, the biological variation appears lower when it is expressed in NGSP/DCCT units, owing to the substantial y intercept (2.15) in the master equation. Consequently, the calculated reference interval is narrower with NGSP data (92%–108%) than with 1 Nonstandard abbreviations: Hb A1c, hemoglobin A1c; NGSP, National Glycohemoglobin Standardization Program; DCCT, Diabetes Control and Complications Trial; CVI, intraindividual CV; CVG, interindividual CV. Letters to the Editor
منابع مشابه
The Analytical Goals for Hemoglobin A1c Measurement in IFCC Units and National Glycohemoglobin Standardization
The variation of a biological measurand can be expressed in the units of the measured concentrations or as a percentage of the absolute variation relative to the mean concentration. For example, given that different metrologic systems are in use for the measurement of human body temperature, this parameter can be expressed in degrees Celsius (Europe), degrees Fahrenheit (US), or degrees Kelvin ...
متن کاملStandardization and analytical goals for glycated hemoglobin measurement.
Glycated hemoglobin (HbA1c) plays a key role in diagnosing diabetes and monitoring the glycemic state. To guarantee the reliability of its measurement at the global level, the IFCC has defined a reference measurement system, based on the definition of the measurand as hemoglobin molecules having a special hexapeptide in common, which is the stable adduct of glucose to the N-terminal valine of t...
متن کاملStatus of hemoglobin A1c measurement and goals for improvement: from chaos to order for improving diabetes care.
BACKGROUND The Diabetes Control and Complications Trial (DCCT) and United Kingdom Prospective Diabetes Study (UKPDS) established the importance of hemoglobin A(1c) (Hb A(1c)) as a predictor of outcome in patients with diabetes mellitus. In 1994, the American Diabetes Association began recommending specific Hb A(1c) targets, but lack of comparability among assays limited the ability of clinician...
متن کاملLetter to the Editor regarding "Achieving comparability with IFCC reference method for the measurement of hemoglobin A1c by use of an improved isotope-dilution mass spectrometry method".
The development of reference measurement methods for hemoglobin A1c (HbA1c) is important for quality assurance in diabetes management. The IFCC reference method using purified proteins as calibration standards is the recommended accuracy-based reference method for the standardization of HbA1c measurement. We developed a highly precise and accurate liquid chromatography-isotope-dilution tandem m...
متن کاملThe role and quality of hb a1c: a continuing evolution.
Since glycohemoglobin was first described in the red cells of diabetes patients in 1968 (1 ), the test has evolved to become an essential tool for prognosis, monitoring, treatment, and diagnosis of diabetes mellitus. An increasing clinical focus together with the development of diabetes management guidelines based on glycated hemoglobin (Hb A1c) 2 necessitated a standardization of the method in...
متن کامل