Respiratory protection for firefighters--evaluation of CBRN canisters for use during overhaul.

نویسندگان

  • Leaton Jones
  • Eric A Lutz
  • Michael Duncan
  • Jefferey L Burgess
چکیده

In the United States, there are approximately 366,600 structural fires each year. After visible flames are extinguished, firefighters begin the overhaul stage of firefighting to smother remaining hot spots and initiate investigations. Typically during overhaul significant ambient concentrations of chemical contaminants remain. However, previous research suggests that the use of air purifying respirators (APR) fitted with chemical, biological, radiological, and nuclear (CBRN) canisters may reduce occupational respiratory exposures. This pilot study used large-scale prescribed burns of representative structural materials to perform simultaneous, side-by-side, filtering and service-life evaluations of commercially available CBRN filters. Three types of CBRN canisters and one cartridge were challenged in repetitive post live-fire overhaul exposure tests using a sampling manifold apparatus. At a flow rate of 80 L/min, nine tests were conducted in the breathing zone for three different exposure durations (0-15 min, 0-30 min, and 0-60 min). Fifty different chemicals were identified for evaluation and results indicate that 21 of the 50 chemicals tested were in the air of the overhaul environment. Respirable particles and formaldehyde were consistently present above the American Conference of Governmental Industrial Hygienists (ACGIH®) recommended exposure level (REL) and threshold limit ceiling value (TLVc), respectively. Each filter effectively reduced concentrations for respirable particulates below the maximum recommended level. Formaldehyde was reduced, but not consistently filtered below the TLVc. These results were consistent across all exposure durations. This study indicates that, regardless of brand, CBRN filters provide protection from the vast majority of particle and gas-phase contaminants. However, due to formaldehyde breakthrough, CBRN filters do not provide complete protection during firefighter overhaul.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Respiratory protection for firefighters--Evaluation of CBRN canisters for use during overhaul II: In mask analyte sampling with integrated dynamic breathing machine.

According to the National Fire Protection Association there were 487,500 structural fires in the U.S. in 2013. After visible flames are extinguished firefighters begin the overhaul stage where remaining hot spots are identified and further extinguished. During overhaul, a significant amount of potentially hazardous chemicals can remain in the ambient environment. Previous research suggests that...

متن کامل

The evaluation of CBRN canisters for use by firefighters during overhaul.

Air-purifying respirators (APRs) have been proposed to provide an additional respiratory protection option for structural firefighters involved in overhaul operations and wildland firefighters, where particulate and aldehyde exposures have been documented. Previous studies (Anthony et al., 2007) developed test methods to evaluate APR cartridges and canisters for use in overhaul activities, wher...

متن کامل

Ultrafine particle exposure during fire suppression--is it an important contributory factor for coronary heart disease in firefighters?

OBJECTIVE Coronary heart disease (CHD) is the primary cause of death among US firefighters during fire suppression. In other populations, exposure to respirable particles, including ultrafine particles, has been widely implicated as a risk factor for CHD. This study is the first to report detailed characterization of respirable particles released by combustion of an automobile and model residen...

متن کامل

Method development study for APR cartridge evaluation in fire overhaul exposures.

In the US, firefighters do not typically wear respiratory protection during overhaul activities, although fitting multi-gas or chemical, biological, radiological and nuclear cartridges to supplied air respirator facepieces has been proposed to reduce exposures. This work developed a method to evaluate the effectiveness of respirator cartridges in smoke that represents overhaul exposures to resi...

متن کامل

Protection of firefighters against combustion aerosol particles: simulated workplace protection factor of a half-mask respirator (pilot study).

The present pilot study investigated the penetration of ultrafine particles originated by combustion of different materials into elastomeric half-mask respirators equipped with two P100 filters. We determined the Simulated Workplace Protection Factor (SWPF) for 11 firefighters wearing elastomeric half-mask respirators and performing activities simulating those conducted during fire overhaul ope...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of occupational and environmental hygiene

دوره 12 5  شماره 

صفحات  -

تاریخ انتشار 2015